background image

InfiniAM Spectral

User guide
H-5800-3919-01-A

Содержание InfiniAM Spectral

Страница 1: ...InfiniAM Spectral User guide H 5800 3919 01 A...

Страница 2: ...erved This document may not be copied or reproduced in whole or in part or transferred to any other media or language by any means without the prior written permission of Renishaw The publication of m...

Страница 3: ...9 1 Introduction 3 1 9 2 Using multiple layer thicknesses 3 1 9 3 Multi laser only crossing lasers 3 1 9 4 Multi laser only intensity 3 2 Introduction 5 2 1 Scope of supply 5 2 1 1 Standard equipment...

Страница 4: ...3 Data storage back up server customer supplied 16 7 Description 17 7 1 Description 17 7 1 1 MeltVIEW 19 7 1 2 LaserVIEW 19 7 1 3 Operating principle 20 8 Commissioning and decommissioning 23 8 1 Comm...

Страница 5: ...Orthographic Perspective view button 45 10 3 2 6 Selected volume dropdown 45 10 3 2 7 Sync current volume button 45 10 3 2 8 Interpolated Pixellated button 46 10 3 2 9 Change displayed data region but...

Страница 6: ...InfiniAM Spectral iv Contents This page is intentionally left blank...

Страница 7: ...r registered trade marks of their respective owners 1 3 Warranty Equipment requiring attention under warranty must be returned to your equipment supplier Unless otherwise specifically agreed in writin...

Страница 8: ...s symbol on Renishaw products and or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal It is the responsibility of the end user to di...

Страница 9: ...three dimensional voxels are produced from five layers the intermittent layers may not be correctly visualised in three dimensional views 1 9 3 Multi laser only crossing lasers Each MeltVIEW sensor h...

Страница 10: ...InfiniAM Spectral Before you begin 4 This page is intentionally left blank...

Страница 11: ...process in Renishaw AM systems 4 DataHUB software suite runs on the data collector PC and converts build data into volumes for viewing 5 InfiniAM Spectral software runs on the viewing PC and enables v...

Страница 12: ...l Engineers or local governing body IIS Internet Information Services IP Internet Protocol IPA Isopropanol Alcohol ISO International Organisation for Standardisation LED Light Emitting Diode MCB Minia...

Страница 13: ...aution is to tell the end user that there is a possibility of damage to the equipment if the described course of action is not followed A Caution will be in sentence case bold text 2 3 3 Note An examp...

Страница 14: ...o refer to the following documents for additional information about other aspects of the InfiniAM Spectral system and Renishaw AM system Installation guide for the applicable Renishaw AM system User g...

Страница 15: ...f manufacture Details of the your Renishaw AM system can be found on the serial plate on the rear of the AM system Details of the MeltVIEW module can be found on the serial plate which is visible when...

Страница 16: ...InfiniAM Spectral 10 Spare parts This page is intentionally left blank...

Страница 17: ...ion PC revision 4 InfiniAM Spectral hardware MeltVIEW module serial number 5 InfiniAM Spectral software version number 6 DataHUB software version number Please quote the details above Details of the A...

Страница 18: ...InfiniAM Spectral 12 Contact details This page is intentionally left blank...

Страница 19: ...ATED WITHIN THIS DOCUMENT WARNING ENSURE THAT A BLANKING PLATE OR THE MELTVIEW HARDWARE MODULE IS FITTED TO THE LASER APERTURE BEFORE TURNING ON THE AM SYSTEM LASER WARNING THE MELTVIEW HARDWARE MODUL...

Страница 20: ...he MeltVIEW module They are as follows Class 4 Custom laser specific label positioned on the MeltVIEW module below the cable connection Figure 1 Electrical warning label positioned on the MeltVIEW mod...

Страница 21: ...he Renishaw AM system Spectrum monitoring range 700 nm to 1700 nm AM emissions monitored Plasma 700 nm to 1040 nm Melt pool 1090 nm to 1700 nm Laser 1050 nm to 1080 nm Optical configuration Co axial i...

Страница 22: ...2 GB DDR4 Solid state drive Minimum N A Recommended 4 TB Hard disk drive 10 TB Ethernet 1 10 Gigabit Ethernet port 6 2 2 InfiniAM Spectral viewing PC specification customer supplied Processor Intel i7...

Страница 23: ...ata collector PC has been set up and all system hardware and software has been commissioned and tested by a Renishaw Service engineer Renishaw has developed the InfiniAM Spectral system Figures 3 and...

Страница 24: ...t enables the user to visually inspect data from the LaserVIEW and MeltVIEW hardware via volume files produced by DataHUB The data can be inspected either as a 3D representation at a resolution of 240...

Страница 25: ...ht Emissions from both plasma and the melt pool are in the near infrared spectrum High optical magnification in a compact form factor ensures the field of view of the system is sufficiently small A ma...

Страница 26: ...metal powder results in a melt pool 18 and plasma 17 Plasma and melt pool both emit in the near infrared spectrum 700 nm to 1700 nm Radiation is emitted in all directions with a small proportion propa...

Страница 27: ...ussing lens 7 Mirror 8 Mirror 9 Collimation lens 10 LaserVIEW system photodiode 11 Fixed mirror 12 Dynamic focussing lens 13 Sparks 14 Powder bed 15 Droplets of molten material 16 Optical window 17 Pl...

Страница 28: ...Cs 1 Single or multiple Renishaw AM systems FTP data via a 1 Gigabit or 10 Gigabit Ethernet connection 2 1 Gigabit or 10 Gigabit Ethernet connection supporting single or multiple Renishaw AM systems 3...

Страница 29: ...IGN TO INDICATE THAT THE SYSTEM IS ISOLATED CARRY OUT SAFE ISOLATION PROCEDURE CHECKS IN ACCORDANCE WITH IEE STANDARDS 8 2 Decommissioning The InfiniAM Spectral system will be decommissioned by a Reni...

Страница 30: ...InfiniAM Spectral 24 Commissioning and decommissioning This page is intentionally left blank...

Страница 31: ...ro P4000 or better RAM memory 32 GB DDR4 Solid state drive SSD Minimum N A Recommended 4 TB Hard disk drive 10 TB Ethernet 1 10 Gigabit Ethernet port Yes 1 3 Is an InfiniAM Spectral viewing PC availab...

Страница 32: ...the data collector PC does not meet this specification Note The data collector PC does not need to be a desktop machine with a monitor it can be accessed through remote desktop connection if needed 9...

Страница 33: ...is progressing or after a build has been completed Note A single data collector PC can accommodate up to six AM systems on either a 1 Gigabit or 10 Gigabit Ethernet Volume files can then be loaded int...

Страница 34: ...build runs The name of the folder will contain the mtt filename as well as the time the build was started Use this folder as the Build data folder Output volume folder this is the folder where the cr...

Страница 35: ...small portion of the build area then it is worth adjusting these to match the build area as the smaller the build area the smaller the resulting volumes Z start and end positions the Z start position...

Страница 36: ...igure 8 Beam dump LaserVIEW photodiode monitors the performance of the laser MeltVIEW plasma photodiode PD1 and MeltVIEW melt pool photodiode PD2 monitor signals from the melting process over differen...

Страница 37: ...tion using the settings provided Once volume creation has been triggered it is possible either to close the application or set up volume creation for another build Note DataHUB Generator does not prov...

Страница 38: ...ted using Renishaw licence manager and restart the PC 10 2 3 DataHUB Monitor DataHUB Monitor Figure 10 shows the progress of volume creation for each build that has been set up using the DataHUB Gener...

Страница 39: ...ce that it should stop adding data to the volumes for that build immediately regardless of how much unprocessed data is available This is useful if an error has been made in setting up volume generati...

Страница 40: ...el and voxel values are calculated using the maximum photodiode signal that falls within the area volume they encompass These volumes are useful for seeing overall trends in the build and highlighting...

Страница 41: ...Spectral software simultaneously 1 Open the InfiniAM Spectral software 2 From the Home page select the New button Figure 11 3 The Select volumes page is displayed To select the volume to be viewed se...

Страница 42: ...yed in the Volume Description box Figure 13 To ease later identification it is possible to add a short descriptive alias If this is not added the file path of the volume will be added automatically to...

Страница 43: ...the volumes in the main viewing mode 10 3 1 InfiniAM Spectral basic navigation controls Use the following mouse controls for navigating around a volume file 1 Pan select and drag using the right mouse...

Страница 44: ...displayed data button Section 10 3 2 3 4 Compare volumes button Section 10 3 2 4 5 Orthographic Perspective view button Section 10 3 2 5 6 Selected volume dropdown Section 10 3 2 6 7 Sync current volu...

Страница 45: ...e 17 this opens the Load volumes dialog and enables further volumes to be loaded Figure 12 Existing volumes can also be removed 10 3 2 3 Control displayed data button 3 Control displayed data button F...

Страница 46: ...sing data according to personal preference This colour scheme will be used for both the histogram and 2D 3D data display The rainbow palette is useful for inspecting data in 2D that has several distin...

Страница 47: ...is being run with a dual monitor set up 10 3 2 4 Compare volumes button 4 Compare volumes button Figure 22 selecting the Compare volumes button opens a new screen which displays three views of the bu...

Страница 48: ...d Compared layers The data in the comparison view is calculated by subtracting the pixel values in the compared layer from those in the reference layer This means that pixels shaded towards red have a...

Страница 49: ...increment buttons or typing the required layer number into the Layer text box The height of that layer in the build is displayed in the Position box Figure 23 Selecting Sync layer locks the difference...

Страница 50: ...e currently selected data ranges from each histogram are both displayed on the plot on the right side of the screen This plot updates dynamically as the palette sliders are adjusted The aim is to adju...

Страница 51: ...dropdown Figure 29 this displays the alias of the currently displayed volume If no alias was provided it displays the name and location of the volume file currently displayed Use the dropdown to sele...

Страница 52: ...on button 9 Change displayed data region button Figure 32 this function is useful for initial inspection of a build as it enables areas of particularly high or low signal to be easily highlighted The...

Страница 53: ...2D mode only the selected data region is displayed 10 3 2 10 Close window button 10 Close window button Figure 34 selecting this closes the window and exits InfiniAM Spectral Figure 34 Close window b...

Страница 54: ...plane views enable the volume data to be inspected in all dimensions in both 2D and 3D The X and Y cut plane views display data at a resolution of 240 m 0 009 in whether in 2D or 3D mode The Z cut pla...

Страница 55: ...2 Show Hide in multiplanar view Figure 38 3 Flip cut plane Figure 39 4 Toggle 2D 3D Figure 40 5 Reset camera Figure 41 6 Screenshot Figure 42 7 Maximise Minimise view Figure 43 8 Cursor position Figur...

Страница 56: ...he volume in front of or behind the cut plane is displayed It also flips which side of the cut plane data is shown in the multiplanar view 4 Toggle 2D 3D button Figure 40 selecting this enables a 2D o...

Страница 57: ...t If the active pane is maximised the view saved will be of the maximised pane 7 Maximise Minimise view button Figure 43 This toggles whether the view occupies a quarter of the screen minimised or the...

Страница 58: ...views there are two and two buttons to make small and large increments and decrements to the cut plane position Figure 46 In the X Y and Z cut plane views there is a slider that can be dragged to mak...

Страница 59: ...Reset camera Figure 51 3 Screenshot Figure 52 4 Toggle build plate Figure 53 5 Maximise Minimise view Figure 54 Note The multiplanar view shows the current position of the X Y and Z cut planes and is...

Страница 60: ...Reset camera button Figure 51 this resets the camera to the default viewing position 3 Screenshot button Figure 52 selecting this opens the Save screenshot dialog This enables capturing of a screensho...

Страница 61: ...55 Operation 5 Maximise Minimise button Figure 54 this toggles whether the view occupies a quarter of the screen minimised or the whole screen maximised Figure 54 Maximise Minimise button...

Страница 62: ...InfiniAM Spectral 56 Operation This page is intentionally left blank...

Страница 63: ...nd what is happening with the progress of volume generation If volume generation hangs or something goes wrong and causes the service to crash then go to the Windows start menu and open Services Scrol...

Страница 64: ...InfiniAM Spectral 58 Troubleshooting This page is intentionally left blank...

Страница 65: ...CARRIED OUT ISOLATE AT THE MAINS POWER SUPPLY BY MOVING THE MAIN SWITCH TO THE 0 OR OFF POSITION AND LOCK IT OFF WITH A PERSONAL PADLOCK ATTACH A VISIBLE WARNING SIGN TO INDICATE THAT THE SYSTEM IS IS...

Страница 66: ...ne Staffordshire ST15 0SH United Kingdom T 44 0 1785 285000 F 44 0 1785 285001 E uk renishaw com www renishaw com For worldwide contact details visit www renishaw com contact H 5800 3919 01 2019 Renis...

Отзывы: