- 17 -
EN
15. Troubleshooting Guide
Problem
Possible cause
Corrective action
No air and no
abrasive.
• Blasting nozzle blocked at
the hand-piece.
• Foot switch connecting
lines kinked.
• Switch set to an intermedi
-
ate position (only on the
2-tanks version).
• Unscrew the nozzle from the hand-piece and blow it out.
• With the nozzle removed, blow out the blasting hose by acti
-
vating the foot pedal.
• Inspect/correct the connection lines.
• Turn the switch until you feel it click into place.
Only air, no or
very little abra-
sive.
• The dosage nozzle in the
mixing chamber is blocked
due to contaminated or
moist sand.
• Mixing chamber filter com
-
bination blocked.
• Abrasive contains impuri
-
ties or is moist.
• Wear protective goggles.
• Unscrew tank lid.
• Remove sand.
• Close the uptake tube (blue tube) in the tank (by bending), so
that no air can escape.
• Hold the sandblasting nozzle on the handpiece closed with
the other hand.
• Using a setting of 4 to 6 bar pressure, activate the foot switch
repeatedly in succession.
• Before re-filling with sand, check the tank and sandblasting
material for contamination or moisture. If necessary replace
with new sand.
• Re-fill with sand and secure the tank lid. (Continue sandblast
-
ing in the usual manner).
Install new filter sets:
- Part no. 90002-8889
25-70 µm
- Part no. 90002-8888
70-500 µm
(Refer to the insert for the appropriate filter set):
• Disconnect the compressed air supply to the mixing chamber.
• Unscrew the plug-in connection.
• Remove the old filter sets.
• Run a thin (1 mm) wire through the opening in the mixing
chamber.
• Install new filter sets as follows (number of components ac
-
cording to the filter set– smooth (colour marked) side facing
the mixing chamber):
1. Screen
2. Filter, thin
3. Filter, thick
4. Screen
5. Spacer
Reinstall the screw-on connections in the reverse order.
Make certain their is no abrasive residue on the threads.
Attention: Never operate the unit without filters!
Do not reinstall used filter sets!
• Replace the abrasive.
Unit blasts con-
tinuously.
• Foot switch connected
incorrectly.
• Valve in foot switch is
defective.
• Inspect/correct the foot switch connection.
• Replace foot switch.
Содержание Basic Master
Страница 3: ...1 2 3 4 5 6 7 8...
Страница 4: ...9 11 10 12 13 14 15 16...
Страница 5: ...17 18 19 20 21...
Страница 6: ......
Страница 42: ...42 RU 90002 8889 25 70 90002 8888 70 500 1 1 2 3 4 5 A apa ec epep He c pa a e a e a 5 6 5 6 1...
Страница 47: ...47 ZH 90002 8889 25 70 m 90002 8888 70 500 m 1 1 2 3 4 5 5 6 4 2 1...
Страница 48: ...48 ZH...
Страница 53: ...53 JA 15 2 4 6 90002 8889 25 70 m 90002 8888 70 500 m 1 mm 1 2 3 4 5...
Страница 54: ...54 JA 5 6 5 6 1...
Страница 59: ...59 KO 15 2 4 6 90002 8889 25 70 m 90002 8888 70 500 m 1mm 1 2 3 4 5 5 6 5 6...
Страница 60: ...60 KO Push in 1 Push in...
Страница 64: ...13b 10b 11b 14b 8 17 16 7 9a 9b 17 15 17 12 13a 11a 10a 14a...
Страница 67: ......