Rev. 1.50, 10/04, page 75 of 448
5.6
Description of Exceptions
The various exception handling operations explained here are exception sources, transition address
on the occurrence of exception, and processor operation when a transition is made.
5.6.1 Resets
Power-On Reset:
•
Condition:
Power-on reset request
•
Operations:
Exception code H'000 is set in EXPEVT, initialization of the CPU and on-chip peripheral
module is carried out, and then a branch is made to the reset vector (H'A0000000). For details,
see the register descriptions in the relevant sections. A power-on reset should be executed
when power is supplied.
Manual Reset:
•
Condition:
Manual reset request
•
Operations:
Exception code H'020 is set in EXPEVT, initialization of the CPU and on-chip peripheral
module is carried out, and then a branch is made to the branch vector (H'A0000000). The
registers initialized by a power-on reset and manual reset are different. For details, see the
register descriptions in the relevant sections.
H-UDI Reset:
•
Source: SDIR.TI[7:4] = B'0110 (negation) or B'0111 (assertion)
•
Transition address: H'A0000000
•
Transition operations:
Exception code H'000 is set in EXPEVT, initialization of VBR and SR is performed, and a
branch is made to PC = H'A0000000.
CPU and on-chip peripheral module initialization is performed. For details, see the register
descriptions in the relevant sections of the hardware manual of the target product.
Содержание SuperH SH-4A
Страница 2: ...Rev 1 50 10 04 page ii of xx ...
Страница 8: ...Rev 1 50 10 04 page viii of xx ...
Страница 116: ...Rev 1 50 10 04 page 96 of 448 ...
Страница 178: ...Rev 1 50 10 04 page 158 of 448 ...
Страница 206: ...Rev 1 50 10 04 page 186 of 448 ...
Страница 231: ...Rev 1 50 10 04 page 211 of 448 Possible Exceptions Slot illegal instruction exception ...
Страница 235: ...Rev 1 50 10 04 page 215 of 448 Possible Exceptions Slot illegal instruction exception ...
Страница 238: ...Rev 1 50 10 04 page 218 of 448 Possible Exceptions Slot illegal instruction exception ...
Страница 408: ...Rev 1 50 10 04 page 388 of 448 Possible Exceptions Inexact Not generated when FPSCR PR 1 ...
Страница 445: ...Rev 1 50 10 04 page 425 of 448 Possible Exceptions Invalid operation Overflow Underflow Inexact ...
Страница 446: ...Rev 1 50 10 04 page 426 of 448 ...
Страница 468: ...Rev 1 50 10 04 page 448 of 448 ...
Страница 471: ......
Страница 472: ...SH 4A Software Manual ...