R11UM0156EJ0240 Rev.2.40
Page 19 of 82
Jul. 28, 2020
PRIME v1.4 Base Node Tool
User Manual
Renesas Electronics Group Confidential
3
.
PC Tool operation procedure
PRELIMINARY
Notice This is not a final specification. Some
parametric limits are Subject to change.
Figure 3.7 Parameters of Data Transmission test
Table 3-3 Operation of Service Node.
ACK type
Operation of Service Node.
None
Single Path mode. Data is transferred from BN to SN only.
ACK request
SN demo application return ACK response to BN.
Loop Back
When SN receives data packet from BN, SN return the same data (data packet).
Data request
BN only specifies the length of data packet which is returned from SN. The
length is specified by “Request length” field.
Table 3-4 TREF settings and the operations.
TREF type
Operation
None
Data packets will be transmitted without Time Reference sub header.
ZCT
Data packets with Time Reference sub header will be transmitted. TREF.SEQ
field and TREF.TIME field show the zero cross timing.
Cert
Data packets with Time Reference sub header will be transmitted. TREF.SEQ
field shows the sequence number of the frame which is next from the TX_SEQ.
TREF.TIME field shows the value which is set at TREF Param dialog.
Fix
Data packets with Time Reference sub header will be transmitted. TREF.SEQ
field and TREF.TIME field show the values which are set at TREF Param dialog.
Table 3-5 AppEmu settings and the operations.
Item
Operation
Auto Execute
Repeating AppEmu data transmission test automatically.
Skip Step6
(Release Connection)
Skipping the
“Step6” of the AppEmu cycle test. Step 6 is a step for
releasing connection.
Get SN Information
Getting the statistics information from SNs
while AppEmu cycle test
running.
“%Y%m%d%H%M%S_prime14_cpx3_pc_bn_sn_statistics.log”
is generated at the start of AppEmu cycle test. BN tool outputs