10
10-102
10.4 TIO (Input/Output-Related 16-Bit Timer)
MULTIJUNCTION TIMERS
32180 Group User’s Manual (Rev.1.0)
TIO0–3 Control Register 0 (TIO03CR0)
<Address: H’0080 031A>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TIO3EEN
TIO2ENS
TIO3M
TIO2M
TIO1M
TIO0M
TIO1ENS
TIO0ENS
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
W
0
TIO3EEN (Note 1)
0: Disable external input
R
W
TIO3 external input enable bit
1: Enable external input
1–3
TIO3M
000: Single-shot output mode
R
W
TIO3 operation mode select bit
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
4
TIO2ENS
0: No selection
R
W
TIO2 enable/measure input source select bit
1: External input TIN5
5–7
TIO2M
000: Single-shot output mode
R
W
TIO2 operation mode select bit
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
8
TIO1ENS
0: No selection
R
W
TIO1 enable/measure input source select bit
1: External input TIN4
9–11
TIO1M
000: Single-shot output mode
R
W
TIO1 operation mode select bit
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
12
TIO0ENS
0: No selection
R
W
TIO0 enable/measure input source select bit
1: External input TIN3
13–15
TIO0M
000: Single-shot output mode
R
W
TIO0 operation mode select bit
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
Note 1: During measure free-run/clear input mode, even if this bit is set to "0" (external input disabled), when a capture signal is
entered from an external device, the counter value at that point in time is written into the measure register. In measure clear
input mode, however, if this bit = "0" (external input disabled), the counter value is not initialized (H’FFFF) upon capture
and, therefore, this bit should be set to "1" (external input enabled) when using measure clear input mode.
Notes: • This register must always be accessed in halfwords.
• Operation mode can only be set or changed while the counter is inactive.
• To select TIO3 enable/measure input sources, use the TIO4 Control Register TIO34ENS (TIO3, TIO4 enable/measure
input source select) bits.
Содержание M32R/ECU Series
Страница 17: ...12 This page is blank for reasons of layout...
Страница 18: ...CHAPTER 1 OVERVIEW 1 1 Outline of the 32180 Group 1 2 Block Diagram 1 3 Pin Functions 1 4 Pin Assignments...
Страница 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Страница 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Страница 795: ...22 22 2 32180 Group User s Manual Rev 1 0 TYPICAL CHARACTERISTICS To be written at a later time...
Страница 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Страница 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Страница 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...