10
10-122
10.4 TIO (Input/Output-Related 16-Bit Timer)
MULTIJUNCTION TIMERS
32180 Group User’s Manual (Rev.1.0)
10.4.13 Operation in TIO Delayed Single-shot Output Mode (without Correction Function)
(1) Outline of TIO delayed single-shot output mode
In delayed single-shot output mode, the timer generates a pulse in width of (reload 0 register set value + 1)
after a finite time equal to (counter set value + 1) only once and then stops.
When the timer is enabled (by writing to the enable bit in software or by external input) after setting the
counter and reload 0 register, it starts counting down from the counter’s set value synchronously with the
count clock. The first time the counter underflows, it is loaded with the reload 0 register value and continues
counting down. The counter stops when it underflows next time.
The F/F output waveform in delayed single-shot output mode is inverted (F/F output level changes from low
to high or vice versa) when the counter underflows first time and next, generating a single-shot pulse wave-
form in width of (reload 0 register set value + 1) after a finite time equal to (first set value of c 1) only
once.
An interrupt request can be generated when the counter underflows first time and next.
The (counter set value + 1) and (reload 0 register set value + 1) are effective as count values. (For counting
operation, see also Section 10.3.10, “Operation of TOP Delayed Single-shot Output Mode.”)
(2) Precautions on using TIO delayed single-shot output mode
The following describes precautions to be observed when using TIO delayed single-shot output mode.
• If the counter stops due to an underflow in the same clock period as the timer is enabled by external input,
the former has priority so that the counter stops.
• If the counter stops due to an underflow in the same clock period as count is enabled by writing to the
enable bit, the latter has priority so that count is enabled.
• If the timer is enabled by external input in the same clock period as count is disabled by writing to the
enable bit, the latter has priority so that count is disabled.
• If the counter is accessed for read immediately after being reloaded pursuant to an underflow, the counter
value temporarily reads as H’FFFF but immediately changes to (reload value – 1) at the next clock edge.
Содержание M32R/ECU Series
Страница 17: ...12 This page is blank for reasons of layout...
Страница 18: ...CHAPTER 1 OVERVIEW 1 1 Outline of the 32180 Group 1 2 Block Diagram 1 3 Pin Functions 1 4 Pin Assignments...
Страница 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Страница 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Страница 795: ...22 22 2 32180 Group User s Manual Rev 1 0 TYPICAL CHARACTERISTICS To be written at a later time...
Страница 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Страница 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Страница 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...