Appendix 4
Appendix
4-13
32180 Group User's Manual (Rev. 1.0)
SUMMARY OF PRECAUTIONS
Appendix 4.8.14 Precautions on Using TOU Single-Shot Output Mode
The following describes precautions to be observed when using TOU single-shot output mode.
• If the counter stops due to an underflow in the same clock period as the timer is enabled by external input,
the former has priority so that the counter stops.
• If the counter stops due to an underflow in the same clock period as count is enabled by writing to the enable
bit, the latter has priority so that count is enabled.
• If the timer is enabled by external input in the same clock period as count is disabled by writing to the enable
bit, the latter has priority so that count is disabled.
• To read the counter on-the-fly, make sure the read timing does not coincide with an underflow of the 16 low-
order bits (8 high-order bits decremented). When reading the counter on-the-fly, take the appropriate mea-
sure to ensure that the read value is correct by, for example, reading the counter twice in succession.
• Because the timer operates synchronously with the prescaler output, a count clock-dependent delay is
included before F/F output is inverted after the timer is enabled.
Appendix 4.8.15 Precautions on Using TOU Continuous Output Mode
The following describes precautions to be observed when using TOU continuous output mode.
• If the timer is enabled by external input in the same clock period as count is disabled by writing to the enable
bit, the latter has priority so that count is disabled.
• To read the counter on-the-fly, make sure the read timing does not coincide with an underflow of the 16 low-
order bits (8 high-order bits decremented). When reading the counter on-the-fly, take the appropriate mea-
sure to ensure that the read value is correct by, for example, reading the counter twice in succession.
• If the counter is accessed for read immediately after being reloaded pursuant to an underflow, the counter
value temporarily reads as H’FF FFFF but immediately changes to (reload value – 1) at the next clock edge.
• Because the timer operates synchronously with the count clock, a count clock-dependent delay is included
before F/F output is inverted after the timer is enabled.
Appendix 4.8 Precautions about the Multijunction Timers
Содержание M32R/ECU Series
Страница 17: ...12 This page is blank for reasons of layout...
Страница 18: ...CHAPTER 1 OVERVIEW 1 1 Outline of the 32180 Group 1 2 Block Diagram 1 3 Pin Functions 1 4 Pin Assignments...
Страница 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Страница 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Страница 795: ...22 22 2 32180 Group User s Manual Rev 1 0 TYPICAL CHARACTERISTICS To be written at a later time...
Страница 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Страница 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Страница 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...