10
10-159
MULTIJUNCTION TIMERS
10.8 TOU (Output-Related 24-Bit Timer)
32180 Group User’s Manual (Rev.1.0)
TOU1 Control Register 0 (TOU1CR0)
<Address: H’0080 0BDA>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TOU10M0
TOU11M0
TOU12M0
TOU13M0
TOU14M0
TOU15M0
TOU16M0
TOU17M0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
W
0, 1
TOU10M0 (TOU1_0 operation mode select 0 bit)
00: Single-shot output mode
R
W
2, 3
TOU11M0 (TOU1_1 operation mode select 0 bit)
01: Single-shot PWM output mode
4, 5
TOU12M0 (TOU1_2 operation mode select 0 bit)
or delayed single-shot output mode (Note 1)
6, 7
TOU13M0 (TOU1_3 operation mode select 0 bit)
10: Continuous output mode
8, 9
TOU14M0 (TOU1_4 operation mode select 0 bit)
11: PWM output mode
10, 11
TOU15M0 (TOU1_5 operation mode select 0 bit)
12, 13
TOU16M0 (TOU1_6 operation mode select 0 bit)
14, 15
TOU17M0 (TOU1_7 operation mode select 0 bit)
Note 1: Use TOU1 Control Register 1 to select between these two modes.
Notes: • This register must always be accessed in halfwords.
• Operation mode can only be set or changed while the counter is inactive.
TOU1 Control Register 1 (TOU1CR1)
<Address: H’0080 0BD8>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TOU1CKS
TOU10M1 TOU11M1 TOU12M1 TOU13M1
TOU15M1 TOU16M1 TOU17M1
TOU14M1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
W
0
TOU1CKS
0: Use prescaler 4
R
W
TOU1 clock source select bit
1: Use external clock (TIN26)
1–7
No function assigned. Fix to "0".
0
0
8
TOU10M1 (TOU1_0 operation mode select 1 bit)
0: Single-shot PWM output mode
R
W
9
TOU11M1 (TOU1_1 operation mode select 1 bit)
1: Delayed single-shot output mode
10
TOU12M1 (TOU1_2 operation mode select 1 bit)
11
TOU13M1 (TOU1_3 operation mode select 1 bit)
12
TOU14M1 (TOU1_4 operation mode select 1 bit)
13
TOU15M1 (TOU1_5 operation mode select 1 bit)
14
TOU16M1 (TOU1_6 operation mode select 1 bit)
15
TOU17M1 (TOU1_7 operation mode select 1 bit)
Notes: • This register must always be accessed in halfwords.
• Operation mode can only be set or changed while the counter is inactive.
TOU1 Control Registers 0 and 1 are used to select operation modes of TOU1_0–7.
To select prescaler 4 as the clock source for TOU1, make sure the TID1 Control & Prescaler 4 Enable Register’s
prescaler 4 enable bit is set to "1". For details, see Section 10.7.3, “TID Control & Prescaler Enable Registers.”
Содержание M32R/ECU Series
Страница 17: ...12 This page is blank for reasons of layout...
Страница 18: ...CHAPTER 1 OVERVIEW 1 1 Outline of the 32180 Group 1 2 Block Diagram 1 3 Pin Functions 1 4 Pin Assignments...
Страница 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Страница 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Страница 795: ...22 22 2 32180 Group User s Manual Rev 1 0 TYPICAL CHARACTERISTICS To be written at a later time...
Страница 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Страница 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Страница 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...