Section 2 CPU
Rev. 6.00 Sep 12, 2006 page 43 of 526
REJ09B0326-0600
Legend:
op:
rn:
IMM:
Operation field
Register field
Immediate data
15
0
8
7
op
RTE, SLEEP, NOP
15
0
8
7
op
rn
LDC, STC (Rn)
15
0
8
7
op
IMM
ANDC, ORC,
XORC, LDC (#xx:8)
Figure 2.9 System Control Instruction Codes
2.5.8
Block Data Transfer Instruction
Table 2.11 describes the block data transfer instruction. Figure 2.10 shows its object code format.
Table 2.11 Block Data Transfer Instruction
Instruction Size
Function
EEPMOV
If
R4L
≠
0 then
repeat @R5+
→
@R6+
R4L – 1
→
R4L
until
R4L = 0
else next;
Block transfer instruction. Transfers the number of data bytes
specified by R4L from locations starting at the address indicated by
R5 to locations starting at the address indicated by R6. After the
transfer, the next instruction is executed.
Certain precautions are required in using the EEPMOV instruction. See section 2.9.3, Notes on
Use of the EEPMOV Instruction, for details.
Содержание F-ZTAT H8/3642A Series
Страница 6: ...Rev 6 00 Sep 12 2006 page iv of xx ...
Страница 8: ...Rev 6 00 Sep 12 2006 page vi of xx ...
Страница 21: ...Rev 6 00 Sep 12 2006 page xix of xx Appendix E Product Code Lineup 522 Appendix F Package Dimensions 524 ...
Страница 22: ...Rev 6 00 Sep 12 2006 page xx of xx ...
Страница 124: ...Section 5 Power Down Modes Rev 6 00 Sep 12 2006 page 102 of 526 REJ09B0326 0600 ...
Страница 188: ...Section 6 ROM Rev 6 00 Sep 12 2006 page 166 of 526 REJ09B0326 0600 ...
Страница 190: ...Section 7 RAM Rev 6 00 Sep 12 2006 page 168 of 526 REJ09B0326 0600 ...
Страница 298: ...Section 9 Timers Rev 6 00 Sep 12 2006 page 276 of 526 REJ09B0326 0600 ...
Страница 378: ...Section 12 A D Converter Rev 6 00 Sep 12 2006 page 356 of 526 REJ09B0326 0600 ...
Страница 446: ...Section 13 Electrical Characteristics Rev 6 00 Sep 12 2006 page 424 of 526 REJ09B0326 0600 ...