Section 10 Serial Communication Interface
Rev. 6.00 Sep 12, 2006 page 338 of 526
REJ09B0326-0600
3. Break detection and processing
When a framing error is detected, a break can be detected by reading the value of the RXD pin
directly. In a break, the input from the RXD pin becomes all 0s, with the result that bit FER is
set and bit PER may also be set.
SCI3 continues the receive operation even after receiving a break. Note, therefore, that even
though bit FER is cleared to 0 it will be set to 1 again.
4. Mark state and break detection
When bit TE is cleared to 0, the TXD pin functions as an I/O port whose input/output direction
and level are determined by PDR and PCR. This fact can be used to set the TXD pin to the
mark state, or to detect a break during transmission.
To keep the communication line in the mark state (1 state) until bit TE is set to 1, set PCR = 1
and PDR = 1. Since bit TE is cleared to 0 at this time, the TXD pin functions as an I/O port
and 1 is output.
To detect a break during transmission, clear bit TE to 0 after setting PCR = 1 and PDR = 0.
When bit TE is cleared to 0, the transmission unit is initialized regardless of the current
transmission state, the TXD pin functions as an I/O port, and 0 is output from the TXD pin.
5. Receive error flags and transmit operation (synchronous mode only)
When a receive error flag (OER, PER, or FER) is set to 1, transmission cannot be started even
if bit TDRE is cleared to 0. The receive error flags must be cleared to 0 before starting
transmission.
Note also that receive error flags cannot be cleared to 0 even if bit RE is cleared to 0.
6. Receive data sampling timing and receive margin in asynchronous mode
In asynchronous mode, SCI3 operates on a basic clock with a frequency 16 times the transfer
rate. When receiving, SCI3 performs internal synchronization by sampling the falling edge of
the start bit with the basic clock. Receive data is latched internally at the 8th rising edge of the
basic clock. This is illustrated in figure 10.26.
Содержание F-ZTAT H8/3642A Series
Страница 6: ...Rev 6 00 Sep 12 2006 page iv of xx ...
Страница 8: ...Rev 6 00 Sep 12 2006 page vi of xx ...
Страница 21: ...Rev 6 00 Sep 12 2006 page xix of xx Appendix E Product Code Lineup 522 Appendix F Package Dimensions 524 ...
Страница 22: ...Rev 6 00 Sep 12 2006 page xx of xx ...
Страница 124: ...Section 5 Power Down Modes Rev 6 00 Sep 12 2006 page 102 of 526 REJ09B0326 0600 ...
Страница 188: ...Section 6 ROM Rev 6 00 Sep 12 2006 page 166 of 526 REJ09B0326 0600 ...
Страница 190: ...Section 7 RAM Rev 6 00 Sep 12 2006 page 168 of 526 REJ09B0326 0600 ...
Страница 298: ...Section 9 Timers Rev 6 00 Sep 12 2006 page 276 of 526 REJ09B0326 0600 ...
Страница 378: ...Section 12 A D Converter Rev 6 00 Sep 12 2006 page 356 of 526 REJ09B0326 0600 ...
Страница 446: ...Section 13 Electrical Characteristics Rev 6 00 Sep 12 2006 page 424 of 526 REJ09B0326 0600 ...