background image

Customer service and 
warranty

A precondition for any warranty 
claims is that the dealer or his 
customer has completed and 
returned the enclosed “

Warranty 

document”

 to REMKO GmbH & 

CO. KG at the time of sale and 
commissioning. 

The units were repeatedly tested 
for perfect functioning at the 
factory. If problems should occur 
which cannot be remedied by 
troubleshooting by the operator, 
your specialised dealer or contract 
partner should be contacted.

Intended use

NOTE

Use for any other purpose 
than that described in these 
operating instructions is not 
permitted.
Non-observance will invalidate 
all liability and warranty 
claims.

NOTE

Adjustments and maintenance 
must be referred to authorised 
specialists.

Important information on 
recycling

The units are operated with 
environmentally-friendly and 
ozone neutral refrigerant R134A.
The refrigerant and oil mixture 
contained in the unit must be 
disposed of properly in accordance 
with the statutory and locally 
applicable regulations.

The units are designed and 
equipped for dehumidification 
purposes. 

The manufacturer is not liable for 
any damage attributed to failure 
to observe the manufacturer‘s 
instructions or applicable statutory 
requirements or unauthorised 
changes to the unit.

ATTENTION

Copyright

Reproduction of this document 
in whole or part in any form 
or use for purposes other 
than that intended is strictly 
forbidden without the prior 
written permission of 

REMKO GmbH & Co. KG

.

Environmental 

protection and 

recycling

Disposal of packaging

Think of the environment when 
disposing of the packaging 
material. 
Our units are carefully packed for 
transport and delivered in sturdy 
cardboard packaging on a wooden 
pallet, if necessary.  
The packaging materials are 
environmentally-friendly and can 
be recycled.
By reusing packaging material, 
you make a valuable contribution 
towards waste reduction and the 
conservation of raw materials.

Only dispose of packaging 
material at the facilities provided.

Disposal of old unit 

 

Our production is subject to 
constant quality controls.

Only high-quality materials are 
used, the majority of which are 
recyclable.

Make your contribution towards 
environmental protection by 
disposing of your old unit in an 
environmentally-friendly manner.

Only dispose of your old unit at 
an authorised recycling facility or 
collection point.

16

REMKO SLE 20

Содержание SLE 20

Страница 1: ...Edition GB T03 REMKO SLE 20 Swimming pool dehumidifier Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...pted Dehumidification 4 6 Safety notices 6 Description of the unit 7 Installation 8 Commissioning 9 Decommissioning 10 Care and maintenance 10 Troubleshooting 11 Electrical wiring diagram 12 Refrigera...

Страница 4: ...r escaping from buildings or materials is absorbed by the ambient air This increases their moisture content and ultimately results in corrosion mould rot peeling of paint coatings and other unwanted m...

Страница 5: ...uilding materials or structures can absorb substantial amounts of water e g bricks 90 190 l m heavy concrete 140 190 l m lime sand bricks 180 270 l m The drying out of moist materials e g masonry take...

Страница 6: ...ise of temperature The time necessary for drying normally does not depend only on the unit capacity but is rather determined by the rate at which the material or parts of the build ing release their m...

Страница 7: ...tion openes integrated at the bottom of the front panel This is transported via a filter evaporator and condenser Heat is extracted from the room air on the cold evaporator and cooled to below the dew...

Страница 8: ...at the bottom of the unit The condensate drain must be connected to the supplied drain connection not fitted A solid or flexible drain connection can be connected The drain hose must always be instal...

Страница 9: ...screws on the sides of the housing Route the cable of the electromagnetic switch through the diaphragm sleeve at the bottom of the unit and connection to terminal 13 and 14 on the control board Refit...

Страница 10: ...should be heavily fouled these can be cleaned carefully with soapy water Do not use a direct jet of water e g high pressure cleaner etc Do not use caustic cleaning agents or those containing solvents...

Страница 11: ...ee The unit operates but no condensate forms Check room temperature The operating range of the unit is between 3 C and 30 C Check the air humidity min 40 relative humidity is necessary Check the sucti...

Страница 12: ...2 Electronic control board Legend M1 Compressor M2 Fan TS1 Condenser sensor TS2 Evaporator sensor Y1 Solenoid valve Legend 1 Compressor 2 Evaporator 3 Condenser 4 Capillary tube 5 Dry filter 6 Solenoi...

Страница 13: ...0 9 Front panel 1109142 2 1 3 4 5 6 8 9 7 Additional condensate container Where it is not possible or difficult to provide a natural condensate drain the unit can be provided with an additional conden...

Страница 14: ...reserve the right to make changes to dimensions and the design in the interest of technical advances Diagram of unit SLE 20 21 10 12 13 15 2 1 23 19 24 25 26 3 9 28 6 8 4 14 27 22 16 17 14 REMKO SLE...

Страница 15: ...Electronics cover 1109109 15 Solenoid valve complete 1109110 16 Condenser NTC sensor 1109111 17 Evaporator NTC thermistor metal 1109112 19 Mains cable with plug 1109124 21 Condenser 1109114 22 Evapor...

Страница 16: ...is not liable for any damage attributed to failure to observe the manufacturer s instructions or applicable statutory requirements or unauthorised changes to the unit ATTENTION Copyright Reproduction...

Страница 17: ...de to the supplied unit without our prior permission Name of manufacturer REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 D 32791 Lage Unit machine type Permanently installed dehumidifier Ser...

Страница 18: ...nature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Unit type Serial number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Unit cleaned outside Unit cleaned insi...

Страница 19: ...ntity g 190 Power supply V Hz 230 1 50 Max nominal current consumption A 2 1 Max power input kW 0 39 Sound pressure level LpA 1m 1 dB A 46 Depth mm 240 Width mm 535 Height mm 600 Weight kg 28 EDP No 6...

Страница 20: ...st a good reliable supplier REMKO a partner who helps solve problems Sales REMKO not only has an extensive sales network in Germany and abroad but also unusually highly qualified sales experts REMKO f...

Отзывы: