Troubleshooting
The units were manufactured using
the latest production methods
and tested repeatedly for perfect
function. If faults should still occur,
the unit must initially be checked
against the following list.
The unit does not start
■
Check setting of operating
switch
■
Check system connection and
local system fuse -230V/1~/50
Hz-
■
Check the mains plug and cable
for damage
■
Check the condensate container,
if provided for filling level and
correct seating
■
Check the integrated hygrostat.
Set the hygrostat to a lower
relative humidity (turn setting
knob fully clockwise)
If the unit does not start, the
integrated hygrostat must be
checked for faults.
Unit switches off
automatically – restarts after
45 minutes and switches off
again after a short time.
■
Does the fan operate when the
unit switches on again after 45
minutes?
■
Is the condenser surface possibly
fouled?
■
Is the suction filter clogged?
■
Is the ambient temperature
possibly above 30°C?
■
Are the intake and outlet grilles
free?
The unit operates, but no
condensate forms
■
Check room temperature
The operating range of the unit
is between 3°C and 30°C
■
Check the air humidity, min.
40% relative humidity is
necessary
■
Check the suction filter for
clogging and clean or replace if
necessary
■
Check the evaporator and
condenser for fouling and clean
if necessary
■
Check the evaporator for ice/
frost formation.
If this is the case, the
automatic defrost function and
temperature sensor must be
checked
The condensate container is
full – however the unit does
not switch off automatically
■
Check that the condensate
container is placed correctly
in the housing and the float is
correctly positioned pointing
towards the electromagnetic
switch
■
Check whether the float of the
water container moves freely or
is possibly damaged
ATTENTION
All work on the refrigeration
system and electrical
equipment must be referred to
an authorised specialist!
The red pilot light (fault)
lights up also when the
condensate container is
empty
■
Check whether the float of the
water container moves freely or
is possibly damaged
NOTE
If the unit does not function
perfectly despite checking, an
authorised specialist must be
contacted.