Installation
For optimal and reliable unit
operation, the following
information must be observed in
any event:
■
The unit must be mounted or
installed in a suitable location
appropriate to the structural
conditions
■
The supplied wall bracket with
suitable fixing material (not
included) must be fixed securely
to the wall
■
The unit must be mounted or
installed horizontally to ensure
unhindered condensate drainage
■
The unit must be mounted or
installed so that the air is able
to be sucked in and blown out
unhindered
■
For optimal unit operation, the
minimum distances from the
unit to the ceiling and to the
floor must be observed
■
The unit should not be installed
in the immediate vicinity of
radiators or other heat sources
■
The room to be dehumidified
must be closed from the
ambient atmosphere
■
Open windows, doors, etc.
as well as frequent entering
and leaving the room must be
avoided as far as possible.
■
For optimal room air circulation
by the dehumidifier, the inlet
and outlet grilles must always
be kept free of dirt and other
obstacles
Condensate drain
The condensate drain is located at
the bottom of the unit.
The condensate drain must be
connected to the supplied drain
connection (not fitted).
A solid or flexible ½“ drain
connection can be connected.
■
The drain hose must always
be installed with a minimum
gradient of 2% to enable the
water to drain unhindered from
the drip tray
■
For an outlet through the
wall, specific preparations are
necessary for correct condensate
drainage prior to installation of
the unit, e.g. the drilling of holes
■
The position of the outlet
connection is shown in the
diagram below
Electrical connection
■
The units are
operated with
230V AC/50Hz
■
Electrical connection takes place
using a supplied mains cable
with safety plug
■
The unit must only be
connected to a socket-outlet
appropriate to the place of
installation and unit rating
ATTENTION
The unit connections must
always be established
in compliance with the
applicable installation
regulations.
ATTENTION
Careful and professional
installation or mounting must
be ensured.
ATTENTION
For securing the compressor
during transport, a cable tie
is attached at the back of the
unit.
This must be removed prior to
installation of the unit.
NOTE
A separate condensate
container with integrated
overflow protection is
available as an accessory.
252
62
Positioning the condensate drain
8
REMKO SLE 20