Design and function
3.1 Unit description
The RXT room air conditioners have a REMKO
RXT...DC AT outdoor unit as well as a RXT...DC IT
indoor unit.
In cooling mode, the outdoor unit serves to output
the heat extracted by the indoor unit from the room
being cooled. In heating mode, the heat taken up
by the outdoor unit can be discharged by the
indoor unit into the room to be heated. In both
operating modes, the output produced by the com-
pressor precisely matches requirements, and
thereby regulates the nominal temperature with
minimal temperature deviations. This "inverter
technology" results in energy savings over conven-
tional split systems and also reduces noise emis-
sions to a particularly low level. The outdoor unit
can be installed in an outdoor area or, providing
that certain requirements are met, an indoor area.
The outdoor unit consists of a cooling cycle with
compressor, fin condenser, condenser fan,
reversing valve and electronic expansion valve.
The outdoor unit is controlled by the regulation of
the indoor unit.
The indoor unit is designed both for both wall and
ceiling-mounted operation in indoor areas. It is
operated by an infrared remote control. The indoor
unit consists of a fin evaporator, evaporator fan,
controller and condensate tray.
B
A
4
3
5
6
1
2
3
7
8
9
Fig. 11: System layout RXT 523-1403 DC
A: Outdoor area / B: Indoor area
1: Indoor unit / 2: Outdoor unit
3: Condensate drainage line / 4: Condenser fan
5: Power supply / 6: Shut-off valve
7: Suction pipes / 8: Injection pipes
9: Control lines
Floor consoles, wall consoles, refrigerant piping,
wired remote controls and condensate pumps are
available as accessories.
Refrigerant piping is used to connect the indoor
unit to the outdoor unit.
1
EEV
RXT 1051 DC
M
M
P S H
T1
T2
T3
TE
T5
P S L
T4
T3
T2
M3
M2
M1
PSL
PSH
T1
V1
M
M
TE
P S H
T1
T2
T3
T5
P S L
M1
M3
T4
T3
T2
M2
PSL
PSH
T1
V1
EEV
2
A
B
A
B
FLT
FLT
FLT
FLT
OEL
T5
T5
Fig. 12: Cooling cycle schematic
A:
Outdoor area
B:
Indoor area
1:
RXT 523-683 DC
2:
RXT 1053-1403 DC
M1:
Condenser fan
M2:
Compressor
M3:
Evaporator fan IT
V1:
Changeover valve C/H
EEV: Electr. expansion valve
FLT: Filter
OEL: Oil return line
PSH: High pressure switch AT
PSL: Low pressure switch AT
T1:
Probe, evaporator IT
T2:
Probe, air inlet IT
T3:
Probe, condenser AT
T4:
Probe, air inlet AT
T5:
Probe, heat gas AT
REMKO RXT...DC
16
Содержание RXT 1053 DC
Страница 62: ...Resistance values for probes T1 T2 T3 and T4 K Ohm K Ohm K Ohm K Ohm REMKO RXT DC 62 ...
Страница 63: ...Resistance values for probe T5 K Ohm K Ohm K Ohm K Ohm 63 ...
Страница 70: ...No Designation 31 Cooling fin 32 Fin motor 33 Refrigerant connections cover REMKO RXT DC 70 ...
Страница 77: ...No Designation 31 Shut off valve mounting plate 32 Condensate tray heating 33 Crankcase heating 77 ...
Страница 80: ...No Designation 31 Crankcase heating 32 Terminal block cover 33 Side panel right REMKO RXT DC 80 ...
Страница 82: ...REMKO RXT DC 82 ...
Страница 83: ......