flow temperature. As a result, the boiler is virtually unaffected by low water
flow. In all cases, maintain a minimum water flow of 0.4 m
3
/h. If progres
sive calorifier control is activated with parameter
, then maintain a
minimum water flow of 0.8 m
3
/h.
4.2.4
Calorifier connection
A calorifier can be connected to the boiler. Our range includes various cal
orifiers.
Important
Contact us for more information.
4.3
Main components
1 Flue gas outlet/air supply
2 Casing/air box
3 Heat exchanger (CH)
4 Flue gas measuring point
5 Ionisation/ignition electrode
6 Mixer tube
7 Combined gas valve unit
8 Air intake silencer
9 Instrument box
10 Siphon
11 Housing for PCBs
12 Fan
13 Water flow pipe
4.4
Control panel description
4.4.1
What each key means
1 Display
2
Escape or
key
3
CH temperature or key
4
DHW temperature or key
5
Enter or
Cancel key lockout
6
Chimney-sweeping keys
Press the 2 and 3 keys simultaneously.
7
Menu keys
Press the 4 and 5 keys simultaneously.
8
On/off switch
Fig.3
Main components
AD-0000011-01
8
7
4
5
5
6
2
1
3
9
11
10
12
13
Fig.4
Control panel
AD-0000065-01
1
2
3
4
5
8
6
7
4 Description of the product
123157 - v.12 - 07022018
19