14
Examples of display symbols:
pump (rotates in operation)
valve (direction of flow black)
collector
hot water storage tank
swimming pool
temperature sensor
heat exchanger
load pause
warning/error message
new information available
(1)
(2)
(3)
(4)
The display (1) shows graphic and text info on
the hydraulic variant, set and measured values
and other text info.
LED lamp (2):
lights up green
- if a relay is closed and the
controller works right
lights up red
-
if the controller is set to
automatic operation and all relays are open
flashes slowly red
- if manual operation
mode is set
flashes quickly red
- if an error occurred.
Entries are made using four keys (3+4), which
are assigned to different functions depending
on the situation.
The ”esc” key (3) is used to cancel an entry or
to exit a menu.
The function of each of the other three keys
(4) is shown in the display line directly above
the keys; the right-hand key generally has a
selection and confirmation function.
Examples of key functions:
+/-
= increase/decrease values
▼/▲
= scroll menu down/up
YES/NO
= approve/reject
Info
= additional information
Back
= to previous screen
ok
= confirm selection
Confirm
= confirm setting
Operation
E.1 Display and input
Description
Hydraulic variants
Solar with cooling 3 (collector cooling)
S1
S2
S3
R1(V1)
R2
Solar with hot water storage tank and solid fuel
boiler and S4
2 East/West solar arrays
solid
fuel
boiler
collector
sensor
radiator
pump
valve
3-way
valve R2 on
heat
exchanger
fan
hot water
storage
tank
auxiliary
heating
flow
heater
pool
S1
S1
S2
S2
S3
S3
S4
S4
R1(V1)
R1(V1)
R2
R2