42
Sentinel Kinetic Advance S, SX - www.regulus.eu
Parameters
Settings
Commissioning Screens
Country
Language
Date
Automatic - Factory set
Time
Automatic GMT/BST - Factory set
Unit configuration
Right Hand
Filter Check
12 months
Summer Bypass
Normal
Mode Names
Normal, Boost, Low, Purge
User Mode
Boost Supply/Extract
50%
Normal Supply/ Extract
30%
Low Supply/Extract
20%
Purge Supply/Extract
100%
Internal RH Mode
On
Internal RH Setpoint
70%
Control Mode
Normal
Frost Protection
Airflow Mode
Mode schedule 1
All days set to 0:00 (on), 00:00 (off) – inactive
Mode schedule 2
All days set to 0:00 (on), 00:00 (off) – inactive
Service Phone
Not Set
Set Lock code
0000
Indoor Temp
25 °C
Outdoor Temp
14 °C
Boost Over-run
Off
Boost Overrun set time
15
Boost Delay
Off
Boost Delay set time
00
LS1/LS2/LS3
User Mode 3 (Boost)
SW1/SW2/SW3/SW4/SW5
User Mode 3 (Boost)
Vent-Wise 1/2/3/4
User Mode 3 (Boost)
Load Pot (60%)
Time Pot (20 m)
Proportional 1/2
Humidity – Boost, Normal (60%)
CO
2
– Boost (2000 ppm), Normal (1000 ppm)
Temperature – Boost (27 °C, Normal 17 °C)
Default settings
Table 2 Default settings