background image

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-961g

Panorama

®

 P33CE Zero Clearance 

Direct Vent Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com

MODEL: P33CE-NG11 Natural Gas
          

P33CE-LP11  Propane

Panorama P33CE

 

-   Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     Warning
FIre or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

02.14.22

Installer:

 Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future 

reference.

C

ertified to/Certifié pour: CSA 2.17-2017

                                            ANSI Z21.88-2017
                                     CSA 2.33-2017

Tested by: 

French Manual: https://bit.ly/3l8nBhl
Manuel en français : https://bit.ly/3l8nBhl

Содержание Panorama P33CE-LP11

Страница 1: ...ediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Warning FIre or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property da...

Страница 2: ...34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Paper Size 5 965 W x 5 71 H Color As shown in artwork DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UN...

Страница 3: ... National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the cur rent CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadia...

Страница 4: ... seven straight days of inactivity the IPI CPI rocker switch will remain in the on position Therefore all that is required to relight the pilot would be to press the on off button on the remote control transmitter from on to off and back to on Once the pilot has re established operation will resume as normal There is no requirement to do anything with the IPI CPI rocker switch If the unit never go...

Страница 5: ...7 CSA 2 17 2017 MAY BE INSTALLED IN MANUFACTURED MOBILE HOMES AFTER FIRST SALE C 4001172 492 492 919 962a NATURAL GAS Model P33CE NG11 PROPANE Model P33CE LP11 Model Modèle P33CE NG11 Model Modèle P33CE LP11 APPAREIL FONCTIONNANT AU GAZ NATUREL Modèle P33CE NG11 Pression d alimentation minimale Pression manifold lev e é é Pression manifold basse Taille de l orifice D bit calorifique minimal é D bi...

Страница 6: ...d Faceplate Dimensions 36 3 4 42 5 16 6 3 8 2 51mm 162mm 1074mm 933mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS Note Gas connection is from the right hand side of the appliance electrical connection on left hand side of the appliance Ametalreceptacleboxissupplied installedwiththeappliancetomakeall120vol...

Страница 7: ...nverted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the ter...

Страница 8: ...ir shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and lig...

Страница 9: ...icing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by a qualified service person A professional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels...

Страница 10: ...ame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if using remote b After approxima...

Страница 11: ...service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l inform...

Страница 12: ...three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control malfunction turn off the IFC device using the ON OFF main switch For instal...

Страница 13: ...one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The ther...

Страница 14: ...lating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote Dimmer Control Light The auxiliary fun...

Страница 15: ...r operating cycle is completed The mode of the fireplace is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using the silver toggle switch located on the fireplace See noted location of CPI IPI Switch The benefits of having CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps...

Страница 16: ...anels Enamel Panels d Log Set Installation e Standard Flush Door f Optional Wall Thermostat g Optional Fan Installation h Safety Screen 8 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer This includes 1 Clocking the appliance to ensure the correct firing rate rate noted on label after b...

Страница 17: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 18: ...less otherwise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions C F G Clearance Dimension Measured From A Front Floor Clearance min 0 Underside of Unit B Sidewall on one side 9 229mm Side Opening of U...

Страница 19: ...t a lower overall height may not be lower than 6 inches from the top of the fireplace opening This drawing is to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Combustible mantel leg clearances as per diagrams below Drywall Man...

Страница 20: ...CE 11 Direct Vent Gas Fireplace installation Mantel Leg Clearances Combustible mantel leg clearances from side of unit as per diagram Top View 0 3 Allowable mantel leg projection 6 3 4 9 Side opening of Unit ...

Страница 21: ...889mm 35 889mm H Framing Height 31 3 4 806mm 31 3 4 806mm I Framing Rise from Floor 0 when not using a surround 0 3 5 16 min w Verona Surround J Framing Depth Vertical Horizontal 23 1 4 591mm Vertical Rise 20 1 4 514mm Rigid 16 1 2 406mm Flex 22 3 4 578mm Vertical Rise 19 3 4 502mm Rigid 16 406mm Flex K Corner Wall Length 39 1 4 996mm 38 15 16 988mm L Corner Facing Wall Width 55 1 2 1410mm 54 1 2 ...

Страница 22: ...extend onto the metal surface of the unit 5 Tile Finish Option 2 If applying a non combustible finishing material tile slate brick stone mantel surround etc the material can be installed directly onto the metal surface of the unit in the area shown below 29 7 16 747mm 21 3 8 542mm Tile Stone Brick Mantel Surround Finish 1 There are 8 eight side nailing strips and one top nailing strip available on...

Страница 23: ...terialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both materials available at your local building or hardware store IMPORTANT Materials used must be NON COMBUSTIBLE 6 If applying a non combustible facing it may be installed over ...

Страница 24: ...Vent Pro Selkirk Direct Temp Amerivent Direct Vent Metal Fab Sure Seal Security Secure Vent and ICC Excel Direct for Horizontal and Vertical Terminations see following Venting Sections for more details Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving...

Страница 25: ...d above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public pro...

Страница 26: ...ations Section Regency Direct Vent Flex Termination Kit Part 946 513 includes all the parts needed to install the P33CE with a maximum run of 2 feet If install ing the P33E with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft or see Rigid Pipe Venting Systems Section for alternate venting arrangements 1 6 7 8 dia flexible liner 2 ft le...

Страница 27: ...g using nails or screws through the nailing strips 3 Assemble the vent assembly by applying Mill Pac to the 4 100mm inner collar of the termination and slipping the 4 100mm liner over it at least 1 3 8 35mm Fasten with the 3 screws drilling pilot holes will make this easier Apply Mill Pac to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the vent terminal at least 1 3 8 35mm ...

Страница 28: ...allation Max Wall Vent Length Thickness inches Required inches 7 1 4 6 10 1 4 9 13 1 4 12 12 1 4 15 7 8 11 14 5 8 Adj Pipe 18 1 4 25 1 4 11 14 5 8 Adj Pipe Alternate Horizontal Termination Caps This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these sy...

Страница 29: ... A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4d...

Страница 30: ... 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal Rigid Piping ...

Страница 31: ...using Contemporary Faceplate unit must be raised 1 Note Must use optional rigid pipe adapter when using rigid vent systems Part 510 994 Rigid Pipe Venting Arrangements Vertical Terminations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using one 90o elbow with rigid pipe vent systems for Propane and Natu...

Страница 32: ...hediagramshowsallallowablecombinationsofstraight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles When using Contemporary Faceplate unit must be raised 1 ...

Страница 33: ...Part 510 994 when using rigid pipe vent systems Refer Rigid Pipe Venting Sys tems Section Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall When using Contemporary Faceplate unit must be raised 1 A vent guard should be used whenever the terminationislowerthanthespecifiedminimum or as per...

Страница 34: ...e 90o elbow Two 45o elbows Option H V H H1 H2 With these options maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max One 90o elbow Two 45o elbows Option H...

Страница 35: ... Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max One 90o elbow Two 45o elbows Option V H V V1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Min C 3 ...

Страница 36: ...bows One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min Withtheseoptions max total pipelengthis30feetwithmin ...

Страница 37: ... Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor 46DVA E45 45o Elbow Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3...

Страница 38: ...onry Fireplaces The shaded area in the diagrams show the allowable vertical terminations 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 2 mm max 610 30 Horizontal Distance Feet Vertical Height feet 2 1 mm max 6 0 Combined min of 8 2 4m 6 152mm max 30 762mm Combined max of 30 9 1m When using Contemporary Faceplate unit must be raised 1 ...

Страница 39: ...re designed with special twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is an available option that must be used in conjunction with the Simpson Dura Vent Direct Vent system 3 Put a bead of Mill Pac inside the outer section of the adapter and on the inner collar Slip the adapter over the existing inner and outer flue collar and fast...

Страница 40: ...that all pipes and elbow con nections are in the fully twist locked position and sealed Diagram 4 NOTE For best results and optimum perfor mance with each approved venting system it is highlyrecommendedtoapply Mill Pac sealant supplied toeveryinnerpipeconnection Failure to do so may result in drafting or performance issues not covered under warranty 8 Slide the appliance and vent assembly towards ...

Страница 41: ... VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 1...

Страница 42: ...agram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop CEILING FIRESTOP FIRESTOP SPACER PART 946 757 Used in conjunction with the 946 755 Vertical Flex Kit and 94...

Страница 43: ...8 flat screwdriver Note Screw should be snug but do not over tighten High Elevation This unit is approved in Canada for altitude to 4500 ft CAN CGA 2 17 M91 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 Pilot Adjustment Periodically check the pilot flames Correct Note If you have an incorrect flame pattern contact your Regency dealer for further instructions Incorrect f...

Страница 44: ... push Burner Assembly to the left and lift out 3 Remove logs and brick panels if installed 4 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 6 Unscrew the pilot orifice with the Allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wren...

Страница 45: ... a panel clip secured with one screw repeat on other side to install opposite panel OPTIONAL ENAMEL PANELS Before installation panels must be handled and cleaned as per instructions noted below Black Enamel Panels Black Enamel panels must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for dam age after installation will not receive consid...

Страница 46: ...sbelowcarefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation Log Kit 431 930 contains the following pieces A 250 Rear Log B 254 Middle Cross Log C 253 Front Left Cross Log D 251 Rear Left Log E 252 Front Right Cross Log F Embers 902 156 G Vermiculite 902 179 H Rock Wool 902 153 I Platinum Embers 946 669 ...

Страница 47: ...k wool and gently place them on the front of the burner tray in the places shown in the photo below Donotcompresstherockwool leaveitloose Separate platinum embers and place them on the front of the burner on and around the rock wool Place rock wool in these 2 locations on the burner tray 251 2 5 2 250 254 2 5 3 250 254 2 5 3 251 2 5 3 250 254 2 5 3 254 252 Cutout 9 Test fire to ensure proper light...

Страница 48: ...oomtemperature 2 Open the front door of the unit see manual for detailed instructions 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Sprinkle the vermiculite and embers around the firebox base 5 Install Log A by lining up the pins on the log bracket with the pin loca tors on Log A Install Log B Install Log C Log A in...

Страница 49: ...D position Log E placement Final install 12 Pull off ember size pieces of rock wool and gently place them on the front of the burner tray in the places shown in the photo below Do not compress the rock wool leave it loose Separate platinum embers and place them on the front of the burner on and around the rock wool 13 Test fire to ensure proper light off make sure flame flows smoothly from one end...

Страница 50: ...n the unit See Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See Diagram 4 To remove the flush door reverse the above steps Diagram 3 Diagram 2 Diagram 1 Diagram 4 Safety Screen 1 To remove the safety screen grasp safety screen on both sides from the bot tom Lift up and out slightly to release from bottom mag...

Страница 51: ...combustible Material 3 1 2 x 36 Nailing Strip 1 2 back from unit face Combustible Material 2 Install four 4 wood screws two 2 on each side of the bracket into the wall studs as shown below Diagram 1 Materials flush w unit Diagram 2 Bracket screw locations on unit Diagram 3 Bracket screw locations Diagram 4 Line up faceplate and bracket Middle Rib on Faceplate Diagram 6 Final Install Diagram 5 Hang...

Страница 52: ... 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power failure the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumst...

Страница 53: ...will be located near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade con nector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector see picture below When complete turn remote receiver to the...

Страница 54: ... on the fan base Ensure the fan blades do not rub against the valve tubing 4 Connect the power cord and fan ground wires to the ground lug Refer to wiring diagram 5 Slide the thermodisc cover assembly on to the bracket clip on the underside of the firebox Thermodisc Clip 6 Install the Fan Control Module FCM on the base of the unit to the left of the gas valve Plug the FCM into the outlet 7 Plug in...

Страница 55: ...ed on the floor of the unit Take care not to damage the insulation on the fan base Ensure the fan blades do not rub against the valve tubing 9 Connect fan ground wire to to the ground lug Refer to wiring diagram 10 Slide the thermodisc cover assembly on to the bracket clip on the underside of the firebox 11 Plug in the fan power cord to the Fan Control Module into the outlet marked Fan Plug the FC...

Страница 56: ... installation TO REMOVE THE FAN 1 Shut the power off 2 Reverse the above instructions Note The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle Diagra...

Страница 57: ...Diagram with Optional Fan SureFire Switch CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges 0 584 622 ...

Страница 58: ...aint is properly cured itisrecommendedthatyouburnyourfireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint the burning off of any oils remaining from manufacturing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass p...

Страница 59: ...ion the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if using optional remote b After approximately 2 seconds...

Страница 60: ...d installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire...

Страница 61: ...teriorportionsofthesystem being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such asWall Straps or plumbers tape for rigidity Log Replacement Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs Th...

Страница 62: ...e materials Do not clean the glass when hot In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement Flush Glass Replacement Remove the flush door front Remove the 4 glass clips from each corner Slide in the new replacement glass Push the 4 glass clips back ontotheframe Theglassmusthav...

Страница 63: ...t out the burner grate assembly 4 Remove the rear log stand by removing the 2 screws Installing Valve 1 Install new valve assembly 2 Reverse steps 7 1 Diagram 5 Lift out Valve Tray Assembly EV1 EV2 Ground 8 Remove valve tray assembly 7 Remove the 12 screws securing the valve tray assembly in place Diagram 4 and then lift the entire assembly out Diagram 4 Valve Tray Assembly Diagram 2 Diagram 3 Rea...

Страница 64: ...as service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these or other conditions arise ...

Страница 65: ...cement Glass w Gasket 911 265 Digital Fireplace Control 911 037 Flame Sense 911 038 Flame Electrode 910 432 Pilot Tube w nuts 911 039 Pilot Hood 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 911 013 Valve Wiring Harness 911 032 Remote Wiring Harness 911 030 Fan Control Module Part Description 911 228 P Remote Receiver 911 175 P Remote Handheld Transmitter 911 127 Receiver Compartment Door 911 ...

Страница 66: ...e Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 433 525 Burner Assy NG LP 82 433 024 Burner Grate Assembly NG LP 83 Rear Log Support Bracket NG LP 85 431 930 Log Set 86 430 097 Air Deflector Left 87 433 018 Air Deflector Right Not available as a replacement part Optional Accessoires Part Description 437 952 Verona Surround Sunset Bronze 437 954 Verona Surround Black 437 957 Verona Sur...

Страница 67: ...P33CE 11 Direct Vent Gas Fireplace 67 notes ...

Страница 68: ...l Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assemble...

Страница 69: ... installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the applian...

Страница 70: ...U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief ...

Страница 71: ...order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made ...

Страница 72: ...72 P33CE 11 Direct Vent Gas Fireplace warranty ...

Страница 73: ...P33CE 11 Direct Vent Gas Fireplace 73 notes ...

Страница 74: ...74 P33CE 11 Direct Vent Gas Fireplace notes ...

Страница 75: ......

Страница 76: ...ease complete the following information Dealer Name Address ____________________________________ ________________________________________________________ Installer _________________________________________________ Phone _________________________________________________ Date Installed ____________________________________________ Serial __________________________________________________ ...

Отзывы: