Regency
®
P33 Gas Log Fireplace
18
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON Dura-Vent DIRECT FLUE GS SYSTEM and
REGENCY DIRECT FLUE SYSTEM (FLEX)
(ULPG with NG/LPG Burner)
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45
o
and one 90
o
elbow (two 45
o
elbows
equal one 90
o
elbow).
Note: Must use optional fl ue adapter (Part # 510-994) when using Simpson Dura-Vent pipe.
• Maintain clearances to combustibles.
• Horizontal fl ue must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.
A fl ue guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
Note: Regency
®
Direct Flue System (Flex) is only approved for horizontal terminations.
IMPORTANT NOTE
If the Burner is a ULPG Burner, a minimum
fl ue rise of 1362mm (total height from the
fl oor) MUST BE adhered to.
INSTALLATION