18)
Reverse steps 5) to 2).
19)
Attach clear label "This unit has been
converted to ULPG" near or on top of
the serial # decal.
20)
Replace yellow "NG" label with red
"ULPG" label.
21)
Check
ULPG
aeration
setting.
22)
Check
for
gas
leaks.
23)
Check inlet and outlet pressures.
24)
Check operation of fl ame control.
25)
Check for proper fl ame appearance and
glow on logs.
26)
Check manual for venting confi gurations
(refer to venting section).
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
16)
Verify that if the conversion is from NG to
LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
17)
Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and main
burner injectors
are appropriate for the gas type.
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
Installer Notice:
These instructions must
be left with the appliance.