Regency
®
P33 Gas Log Fireplace
29
CONVERSION KIT #434-967 FROM NG TO ULPG
for P33 using SIT 820 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each ULPG Conversion Kit contains:
Qty. Part #
Description
1
904-529 5/32"
Allen
Key
1
904-575 Burner
Orifi
ce
#55
1
910-037
LPG Injector (Pilot Orifi ce)
1
918-272
"Converted to ULPG"
label
1
918-273 Red
"ULPG"
label
1
918-548 Instruction
Sheet
6)
Pull off the
pilot cap to
expose the
pilot orifi ce.
Remove the 2 screws, push Burner
Assembly to the left and lift out.
Installation of ULPG Conversion
Kit:
1)
Shut off the gas supply.
2)
Remove the louvers (and bay door if it is
installed).
3)
Open the fl ush door and remove the door.
4)
Remove the logs, embers/rockwool.
5)
Remove the 2 screws holding the Burner
Assembly to the fi rebox base. Push the
Burner Assembly to the left and lift out.
7)
Unscrew the pilot orifi ce with the allen
key and replace with the LPG pilot orifi ce
in the kit and replace pilot cap.
8)
Remove burner orifi ce with a 1/2" wrench
and discard. Use another wrench to hold
on to the elbow behind the orifi ce.
9)
Reinstall new burner orifi ce ULPG
stamped #55 and tighten.
10)
Turn control knob to the “OFF” position.
11)
Remove the black protection cap by hand
from the high-low knob (Fig.1).
Fig. 1
12)
Insert a 5/32” or 4mm Allen wrench
into the hexagonal key-way of the
screw (Fig. 2), rotate it counter-
clockwise until it is free and extract it.
13)
Check that the screw is clean and if
necessary remove dirt.
14)
Flip the screw (Fig. 3).
Fig.2
Fig.3
Burner Orifi ce
15)
Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
Fig.4
INSTALLATION