39
Regency Horizon™ HZ30E-1 Gas Fireplace
INSTALLATION
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(for mobile home)
Star washer
OPTIONAL FAN WIRING DIAGRAM
WITHOUT PROFLAME GTMF SYSTEM
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
*Speed Control
Switch with lead wires
Wire Nuts
14 AWG wire
*Wire Clamp
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
Wire
Black
White
Ground
*Receptacle Box
inside stove
~
*Receptacle
(dedicated use
by unit fan only)
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Ground
Green
Neutral
Live
Black
Black
Fan Thermodisc
(normally open)
Ground
120V AC
60 Hz
Fan
Black
Black
Red
Power
Switch
Receptacle
in Unit
To Fan (see above)
Ground
L1
N
Black
Red
Ground
Break Tab
Copper terminals
Black
Do Not Break Tab
on Neutral (silver terminals)
Fan
Speed
Control
AC Adaptor (see AC Adaptor in