12
Regency Horizon™ HZ30E-1 Gas Fireplace
INSTALLATION
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The nailing Strips must be correctly positioned and attached before unit is
slid into position.
NAILING STRIPS
The nailing strips come attached to the unit. There is 1 plate on each side, 1
on the top, and one on the bottom that can be folded out as required.
The top and side nailing strips are secured to the framing. The bottom
nailing strip is secured to the unfi nished fl oor - if installing the unit directly
on the fl oor.
IMPORTANT NOTE
Framing depth measurement is noted with
the nailing strips set as far forward on the
fi rebox as possible. The nailing strips can
be adjusted back up to 1-1/2” to allow for
varying thicknesses in non-combustible
material & wall fi nishes.
Nailing Strips
INSTALLATION ACCESS PANEL
The unit is equipped with a removable access panel for pre-fi nish installation
of optional components - this panel is located on the lower front face.
1)
Remove 2 screws to remove access panel.
2)
Easier access to gas connection with panel removed.
3)
Install any optional components with access panel removed.
4)
Reinstall access panel with 2 screws - prior to installing any facing material
Note:
Access panel is no longer usable once facing material installed.
Installation Access Panel
Screw Locations