38
Regency Horizon™ HZ30E-1 Gas Fireplace
INSTALLATION
PROFLAME REMOTE SYSTEM GTMF WITH OPTIONAL FAN
Ground
Green
Neutral
Live
Black
Black
Fan Thermodisc
(normally open)
Ground
120V AC
60 Hz
Fan
Black
Black
Red
Proflame System
Configuration
886 GTMF
Wire Diagram
SureFire™ Switch
0.584.907
880
880
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Thermostat
(Optional)
See optional wall thermostat
installation in this manual.