LRI6E / HRI6E Direct Vent Gas Insert
|
28
installation
The LRI6E / HRI6E use a heat exchanger and efficient combustion technol-
ogy to provide extreme heating efficiencies. The more efficient an appliance
becomes, the lower the flue gas temperatures becomes.
On start-up, flue temperatures are required to initiate venting action.
Here are some considerations when setting up the LRI6E / HRI6E:
1)
When operating the unit in temperatures below 50
°
F, run the pilot in
"Standing Pilot" mode, by setting the Surefire™ switch to ON.
The switch is located to the bottom left of the Firebox Door.
2)
Move the switch to the right to run in Standing Pilot mode, to the left to
run in Intermittent Pilot (electronic ignition) mode. This will aid in keeping
the flue slightly warmer than the outside air, making start up a smoother
process.
STANDING PILOT AND HEAT EXCHANGE RETURN
Exhaust Ba
ffl
e
Screws help to locate
the Exhaust Baffle when
installing in the Firebox
Exhaust Baffle
Exhaust Baffle Screws (both sides)
Exhaust Ba
ffl
e
Screw
Heat Exchanger Return
Heat Exchanger Return
HEAT EXCHANGE RETURN
NOTE:
Only installed at elevations of 35 feet maximum vent run.
ADDING THE HEAT EXCHANGER RETURN
1)
Remove the panels if they are already installed. Remove one screw
in the upper left and upper right of the firebox. If the unit has been
previously operated, spray these screws with WD-40. Once the screws
have been removed, lower the front edge of the exhaust baffle and pull
towards you. There are 3 screws at the rear of the exhaust baffle that
help to position the baffle and keep it straight during operation.
2)
Install the heat exchange return as shown.
3)
Reinstall the exhaust baffle.