Grandview® G800C Gas Fireplace
| 61
installation
LP CONVERSION
G800C
2
12.03.19
920-183
1
9) Verify that if the conversion is from NG to
LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
20)
Re-assemble the black protection
cap (Fig. 6).
Fig. 6
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
21)
Reverse steps 6 - 1.
Fig.4
Fig.3
16)
Check that the screw is clean and if
necessary remove dirt.
17)
Flip the screw (Fig. 3).
18) Using the Allen
wrench as shown in
Fig.4, rotate the screw
clockwise until snug,
do not overtighten.
WARNING!
Do not over tighten the screw.
Recommended to
grip the wrench by the short side.
22) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
23) Replace yellow "NG" label with red
"LPG" label.
24) Reinstall burner assembly.
25) Adjust aeration accordingly—see
manual for details. Aeration must be set
to 3/16" for LP.
26) Reverse steps 4–1.
27) Check for gas leaks.
28) Check inlet and outlet pressures.
29) Check operation of flame control.