background image

Grandview

® 

G800C  

Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com

MODEL: G800C 
Medium DV Gas Fireplace

 

    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 

    WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

  •  Do not touch any electrical switch: do not use any phone in your building.
    Leave the building immediately.
  •  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
  • If you cannot reach your gas supplier, call the fire department.
   

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

920-182

    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

01.06.20

Installer: 

 

Please complete the details on the back cover and leave 
this manual with the homeowner.

Homeowner:

 

Please keep these instructions for future reference.

Certified to/Certifié pour: ANSI Z21.88-2017
                                        

Tested by: 

     Warning
Fire or Explosion Hazard
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Содержание Grandview G800C

Страница 1: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 920 182 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 01 06 20 Installer Please complete the details on the back cover and leave this manual with the homeo...

Страница 2: ...the warmth and charm of a wood fireplace at the flick of a switch The Grandview G800C has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ...1 and the current National Electrical Code ANSI NFPA 70 in the U S A This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 This appliance ma...

Страница 4: ... other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspected into operation Adjust the thermostat so appliance is ...

Страница 5: ...gid Pipe and FPI Direct Vent System Flex 47 Venting Arrangements Vertical Termination Rigid Pipe System and Vertical Flex Kit to Same Limitations 48 Horizontal Terminations Two 2 90 Elbows 49 Horizontal Terminations Three 3 90o Elbows 49 Vertical Venting with Two 2 90o Elbows 50 Vertical Venting with Three 3 90o Elbows 50 Vertical Terminations Three 3 90 Elbows Rigid Pipe 4 x 6 5 8 51 Venting Arra...

Страница 6: ...ler l appareil selon la norme 24 CFR Part 3280 Manufactured Home Construction and Safety Standard Si ces normes ne sont pas pertinentes utilisez la norme ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard ou ANSI A119 2 ou NFPA 501C Standard for Recreational Vehicles Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil peu...

Страница 7: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 8: ...AN FRONT 32 5 8 827mm CLEAN FRONT 1 5 8 41mm 33 7 8 862mm OUTSIDE FINISH 1 5 8 41mm 29 7 8 759mm 25 1 2 648mm 36 3 8 924mm 35 1 8 892mm 18 7 8 480mm 17 1 2 446mm 7 1 2 192mm 1 1 2 39mm 28 7 8 734mm 11 1 4 287mm 11 1 4 287mm ELECTRICAL INLET 4 101mm 6 5 8 170mm 18 457mm 19 481mm NON COOL WALL 16 7 8 429mm COOL WALL 7 5 8 195mm 1 1 4 32mm 32 1 2 823mm FIREPLACE OPENING GAS INLET 37 3 4 959mm 34 3 4 ...

Страница 9: ...ITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICA...

Страница 10: ...moved for servicing must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace 9 Wear gloves and safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modifie...

Страница 11: ...ow cradle extender knob 2 Slide the extender knob over the pilot on off knob located on the gas valve See below 3 Follow instructions on how to light the pilot in this manual or the lighting plate located on the underside of the unit 4 Once the pilot is lit remove the extender knob and put it back into the cradle for future use On off pilot knob on gas valve Extender knob slid over on off pilot kn...

Страница 12: ...oustic signal from the receiver confirms the reception of the com mand Low Battery Detection Transmit ter The duration of the remote control batteries depends on many factors the quality of the batteries used the number of ignitions of the appliance etc If the transmitter batteries are low the light intensity of the LED see Fig 5 will de crease when you press the ON OFF key to alert you to this co...

Страница 13: ...stallation Glass door removal 1 To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up and...

Страница 14: ...e Nailing Strips Refer to Unit AssemblyPriortoInstallation Section NOTE Must be done before installing unit into place 3 Install vent Refer to Venting sections 4 Makegasconnections Testthepilot Mustbe as per Diagram Refer to Pilot Adjustment section Convert to propane if desired Refer to Gas Line Installation and Conversion Kit from NG to LPG sections 5 Make electrical connections to receptacle su...

Страница 15: ...late See descriptive diagrams on the next page Clean Front Outside Finish 18 Cool Wall installation Part 1 Cool Wall conversion 19 Cool Wall Clearances 20 Cool Wall Mantel Clearances 21 Cool Wall Mantel Leg Clearances 22 Cool Wall Application Framing 23 Chase Vent Installation 24 Clean Front Installation Clearances 25 Clean Front Installation Mantel Clearances 26 Clean Front Installation Mantel Le...

Страница 16: ...ombustible Finishing Clean Front Standard Install Non vented chase Non combustible board required Combustible framing Cool Wall Install Vented chase Combustible material can be used all around the fireplace Combustible framing Clean Front Clean Front Outside Finish w Finishing Trim Outside Finish w Faceplate ...

Страница 17: ...it and discard 3 Slide out tab as shown to remove recycle part 4 Insert a large slotted screwdriver into the slot in between front and back tabs bend the three 3 tabs up 90 towards the front DO NOT REMOVE TABS 5 Bend the rear three 3 tabs up 90 towards the back of the unit 6 Flip top panel 180 and reinstall to top of unit with four 4 screws in loca tions shown below ...

Страница 18: ...llations Clearance Cool Wall Clean Front Measured From A Mantel Height min 0 0mm Top of Fireplace Opening B Sidewall 6 152mm Side of Fireplace Opening C Ceiling 47 1 2 1207mm Top of Fireplace Opening D Mantel Depth max 14 356mm Front of Fireplace Opening E Alcove Width 84 2134mm Wall to Wall Minimum F Alcove Depth 36 914mm Front to Back Wall Maximum G Convection Air Outlet 66 sq Top Front of Enclo...

Страница 19: ...earances G800C A B C From Top of Fireplace Opening 32 1 2 826mm 10 254mm 5 127mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening A B 14 To Floor 10 Inches 5 C 2 7 14 Mantel leg Allowable mantel leg projection TopView Side opening of fireplace Mantel leg Mantel leg 2 51mm 3 76mm 1 3 4 44mm 32 1 2 826mm overall fireplace width Cool Wall Mantel Leg Clearances See framing dimens...

Страница 20: ...iling Enclosure 80 2032mm S Rear Vent Vent Centerline Height Rear 29 737mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to Corner of Unit 2 3 4 70mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth Q P R M N O S S ...

Страница 21: ... Minimum height of enclosure from base of appliance is 80 CHASE VENTING A minimum 66 in2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outlet s Regency Chase Vent Custom chase vent Reveal at the chase top ...

Страница 22: ... 8 wide to accomodate the Chase vent The top of the Chase vent opening must be 1 5 or less from the top of the chase enclosure Fasten the Chase vent with screws and construction adhesive If the optional Regency chase vent is not being used a minimum 66in2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including a reveal at the ...

Страница 23: ... of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800C Clearance Requirements Clearance Dimension Measured From A Mantel Height min 11 1 2 292mm Top of Fireplace Opening B Sidewall...

Страница 24: ...e shown in the Diagram on the right Note Ensure the paint that is used on the mantel and the facing is High Quality or the paint may discolour Mantel Clearances G800C A B C D From Top of Fireplace Opening 32 1 2 826mm 20 1 2 597mm 15 1 4 470mm 11 1 2 292mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 19 7 12 A B 14 To Floor 12 24 Inches C D Non Combustible Material Min ...

Страница 25: ...s 32 3 4 832mm NO FACING OR FINISHING MATERIAL IN THIS AREA No Combustible Materials in this Area 37 1 2 953mm 11 1 2 292mm 3 76mm 3 76mm 30 7 8 784mm 1 5 8 41mm See framing dimensions on next page Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826mm Overall Fireplace width 1 1 2 2 38mm 51mm ...

Страница 26: ...62 1575mm S Rear Vent Vent Centerline Height Rear 29 673mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to corner of unit 2 3 4 70mm Non combustible Height 11 1 2 292mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed hea...

Страница 27: ... Instructions Optional Clean Front Trim Optional Clean Front Trim Install Instructions 1 Desserrer les quatre 4 vis qui fixent les brides de clouage gauche et droite à l appareil 2 Slide the left and right tiling flanges onto the front of the fireplace Use the slots to center with the screw securing the Nailing Flanges 3 Tighten screws down 4 Slide the Bottom Tiling Flange against thebottomofthefi...

Страница 28: ...y related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800C Outside Finish Clearance Requirements Clearance Dimension Measured From A Mantel Height min 10 254mm Top of Fireplace Opening B Sidewal...

Страница 29: ...ntel Clearances G800C A B C D From Top of Fireplace Opening 34 754mm 19 483mm 15 381mm 10 254mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace 12 1 7 A B 14 To Floor 12 24 Inches C D Non Combustible Material Min 10 H 254mm 9 Outside Finish Installation non Cool Wall Mantel Leg Clearances Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4...

Страница 30: ... Chase Ceiling Rear 62 1575mm S Rear Vent Vent Centerline Height Rear 29 673mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to Corner of Unit 2 3 4 70mm Non combustible Height 10 254mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of t...

Страница 31: ...ew G800C Gas Fireplace 31 installation Outside Finish Finishing Finishing Material may be brought to the top and side edges of the fireplace Finishing material can protrude past the front face of the fireplace ...

Страница 32: ...g flange These tabs are used to stop finishing material from interfering with the faceplate mounts Faceplate Finishing The finishing material can be brought to the top of the fireplace A 1 2 gap must be maintained on the sides to allow the Faceplate to be installed The finishing material must not protrude past the front face of the fireplace Follow the steps below to install Top and Side Nailing F...

Страница 33: ...he arms on the Face Plate on top of the mounting tabs Adjust left and right to center the Face Plate NOTE Do not to touch the Face Plate without clean soft gloves Dirt or oils can be transferred onto the finish and become permanent Critical Finishing Gap Faceplate Finishing A 1 2 gap must be maintained on the sides of the fireplace to allow the Face Plate to be in stalled and removed Do NOT finish...

Страница 34: ...op into the slot on the right 5 Fold the tab down to secure Right Side Finishing Trim Install Instructions 1 Bend the four tabs on the outer box front forward There are two tabs per side These tabs are the mounts for the faceplate or finishing trim 2 Bend the two tabs on the top nailing flange down 3 Bend the tabs on the left and right nailing flanges forward There are two tabs per nailing flange ...

Страница 35: ...nishing Trim to be installed and removed The finishing trim has adjustment for material to protrude up to 1 4 past the front of the fireplace Top Nailing Flange Tabs folded down 3 4 Finishing Trim Top View Mounting Tab Folded forward Nailing Flange folded forward Install the faceplate by resting the arms on the finishing trim on the top of the mounting tabs Adjust left and right to center the fini...

Страница 36: ... used including the backing mate rial The depth of finishing material can be adjusted in 1 4 increments 11 4 Finishing Material Depth Flush Setting 1 Determine the required depth set ting for the materials being used 2 Once the setting has been chosen install the Left and Right Nailing Flanges with 2 screws on each Flange 1 3 4 1 2 1 4 Front of Fireplace Nailing Flange Parts Top Nailing Flange Sta...

Страница 37: ...ISH Finishing Material Backing Material Drywall etc Flush Finishing Material CLEAN FRONT 3 Slot the Standoff Deflector onto the back screws then secure the with a screw through the remaining front hole on each flange 1 Screw one screw into the rear hole on each Side Nailing Flange 2 Install the Top Nailing Flange with 4 screws Top Nailing Flange Standoff Deflector Nailing Flange Installation ...

Страница 38: ...ces to combustibles Inadequate air space could cause overheating and fire The appliance is designed to be used with 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing Material Facing and or finishing materials must never overhang into the glass opening Facing ...

Страница 39: ...ottom screws to remove outside collar from the back of the unit See Diagram 3 3 Remove the four 4 top screws and loosen the two 2 bottom screws to remove in the inner collar from the back of the unit See Diagram 3 Important Loosen bottom screws only and slide inner and outer collar up and off unit Diagram 1 Diagram 3 Diagram 4 Top of Unit Diagram 2 Back of Unit 4 From the top of the unit remove th...

Страница 40: ...to the two 2 loosened screws and tighten all six 6 screws 9 Install the top cover plate removed from the top in Step 4 to the back of the unit Slide the plate onto the two 2 loosened screws and tighten all 4 screws 10 Install inner collar removed from the back in Step 3 to the top Slide collar onto loosened screws and tighten all six 6 additional screws 11 Install outer collar removed from the bac...

Страница 41: ...iance Each direct vent gas appliance must use it s own separate vent system Common vent systems are prohibited Vent Restrictor Installation tooltip Diagram 2 Vent restrictor located on top exhaust assembly 1 Determine the venting configuration 2 Go to venting arrangements section in the manual to determine if a vent restrictor setting is required If required proceed to Step 3 3 Loosen the two scre...

Страница 42: ...ach side of center line extended above meter regulator assembly J Clearance to service regulator vent outlet K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public proper...

Страница 43: ...N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LB...

Страница 44: ...mination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523...

Страница 45: ...um continuous vent maximum horizontal length of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 44 1 1m Horizontal Feet Max 36 0 9m Fle...

Страница 46: ...r Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent Ameri can Metal Products Olympia Ventis DV Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has...

Страница 47: ...s equal one 90o elbow Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe venting systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter FPI Flex Vent 4 inner diameter 6 7 8 outer diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent gua...

Страница 48: ...ements Vertical Termination Rigid Pipe System and Vertical Flex Kit to Same Limitations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with rigid pipe vent systems for Propane and Natural Gas 2 6 10 4 8 12 Vertical Height Feet Horizontal Feet 8 10 12 14 16 18 20 22 24 26 28 30 32 34 3...

Страница 49: ...talled Required when using rigid venting Lengths do not include elbow indicated Horizontal Terminations Three 3 90o Elbows Lengths do not include elbow indicated One 90o elbow Two 45o elbows Option V H V V1 H H1 With these options max total pipe length is 30 feet with min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbowsisrequired A 0 Min 1 Max 1 M...

Страница 50: ... Min 5 Max 4 Min D 3 Min 6 Max 5 Min E 4 Min 7 Max 6 Min F 5 Min 8 Max 7 Min Lengths do not include elbow indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H H1 V V1 With these options maximumtotalpipelength is 30 feet with minimum of 10 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 0 Min 2 Max 2 ...

Страница 51: ... Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated No Vent Restrictor Installed Required when using rigid ventin...

Страница 52: ... collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 Co linear Adapter with flashing Flex Liner Exhaust Flue ...

Страница 53: ...ENTIAL MANUFACTURED HOMES 30 Max 8 Min 44 3 4 30 Horizontal Distance Feet Vertical Height feet 8 Min 44 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max Combined min of 8 6 max 44 Combined max of 30 30 Horizontal Distance Feet Vertical Height feet 2 max IMPORTANT As shown below the unit can only be vented from the top not from the rear ...

Страница 54: ...If the Snorkel Termination must be installed below grade i e basement application proper drainage must be providedtoprevent water from enter ing the Snorkel Termination Refer to Diagram 4 Do not attempt to en close the Snorkel within the wall or any other type of enclosure Unit Installation with Horizontal Termination Install the vent system according to the manufacturer s instructions included wi...

Страница 55: ...oftheapplianceflueexit and mark the location Diagram 1 where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previouslydrilledintheceiling andmark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing willobstructthe v e n t i n g system You may wish to relocate the a p p l i a n...

Страница 56: ... framing out a square to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french Offset Chart Direct Vent System Flex Installation Procedures 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline ...

Страница 57: ... pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 16 Install termination cap by twist locking...

Страница 58: ...am 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To install the cei...

Страница 59: ...olledbyaregulator built into the gas control and should be checked at the pressure test point Note To properly check gas pressure bothinletandmanifoldpressures should be checked using the valvepressureportsonthevalve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pr...

Страница 60: ...f LP Conversion Kit 10 Re install pilot cap and pilot retainer clip 11 Remove burner orifice with a 3 8 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice 12 Reinstall new burner orifice LPG stamped 53 and tighten 7 Remove the pilot retainer clip below the pilot cap 9 Unscrew the pilot orifice with the Allen key then replace with the LPG pilot orifice provided in ...

Страница 61: ...at the screw is clean and if necessary remove dirt 17 Flip the screw Fig 3 18 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten WARNING Do not over tighten the screw Recommended to grip the wrench by the short side 22 Attach the label This unit has been converted to LPG near or on top of the serial decal 23 Replace yellow NG label with red LPG label ...

Страница 62: ... shown below Note Do not install the firebed grate media vermiculite embers and logs until the brick panels are installed Brick panels will discolor a little during normal operation This is normal and should not be considered a defect tooltip Brick Clip Panel Inside top of firebox 3 Loosen 2 screws on pilot assembly in locations shown below Slide pilot shield towards the back of the unit and remov...

Страница 63: ...ittle during normal operation This is normal and should not be considered a defect All hand and fingerprints MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty G800EC G800C tooltip B...

Страница 64: ...o not use the unit until they are replaced Broken logs can interfere with the pilot operation The G800EC G800C log sets 761 930 for Oak 761 932 for Birch contain the following pieces 1 6 8 2 3 4 9 11 5 10 12 7 NOTE Panels brick steel or enamel must be installed prior to installing the log set 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not forc...

Страница 65: ...ulled forward and to the right while contacting the end and curved parts of the burner 6 Install Log 2 on left log support plate Line up the pins on the plate with the pin hole on the log 7 Install Log 3 on right log support plate Line up the pins on the plate with the pin hole on the log 8 Install Log 4 diagonally across Log 2 Rest Log 4 in the notch out on Log 2 as shown Diagram 5 Install Log su...

Страница 66: ...og 7 should land on the pin of Log 1 The bottom of Log 7 will rest on the log grate 12 Install Log 8 at the front of the log grate The cutouts in Log 8 should rest in the 4th 5th prongs from the right of the log grate 13 Install Log 9 to the right of Log 5 The cutout in Log 9 will rest in the 2nd prong from the right on the log grate Diagram 13 Install Log 7 Diagram 11 Install Log 5 Diagram 14 Ins...

Страница 67: ...og grate on the firebox floor as shown 16 Install Log 12 on the firebox floor slide under Log 7 as shown 17 Test fire to ensure proper light off make sure flame flows smoothly If there is any flame hesitation check that area for any blockage of the burner ports Diagram 17 Install Log 11 Diagram 19 Final Installation Diagram 18 Install Log 12 12 7 11 G800EC G800C ...

Страница 68: ...ay in one even layer Important ensure that at least 50 of the gas burner porting remains uncovered Do not cover the pilot area BURNER PORTING PILOT 4 If using volcanic stones as additional media add a maximum of 13 as shown below Important Volcanic stones should not cover any of the gas burner porting or pilot areas Note The optional brick steel or enamel panels must be installed prior to the crys...

Страница 69: ...anty Pull lever forward to open push back to close Air shutter lever located in the center of the unit under the firebox Electrical Access and Installation The electrical access panel is on the right side of the unit when facing the front of unit 1 Remove panel by removing three 3 screws 2 Remove center knockout to run cable through the access panel and install supplied clamp 3 Attach wires from c...

Страница 70: ...f wire but if you wish to go with a longer run use the Thermostat Wire Table 2 Connectthewiretoa wallswitchandinstall into the receptacle box Also attach wires to the valve as shown on wiring diagrams CAUTION Do not wire millivolt wall switch wire to 120V wire Optional Wall Thermostat A wall thermostat may be installed if desired connect the wires as per the wiring diagram Use table below to deter...

Страница 71: ...for details Installing an Optional Wall Switch or Thermostat 2 Locate the black wire running from the valve to the unit on off switch Unclip the wire holder clip and remove the black wire from the clip 3 Break the connection between the inline wire connectors on the black wire The wall switch or thermostat wiring will run to these two connec tors 4 Route the wiring for your wall switch or thermost...

Страница 72: ...trical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong from this plug Wiring Diagram With and Without Thermostat Remote Control Caution Label all wires prior to discon nection when servicing controls ...

Страница 73: ... INSTALLATION Diagram 5 DFC wires Diagram 6 ground wires 3 From the back of the unit remove 4 screws from the fan access panel locations shown below 4 Push fan speed control module towards the front of the unit this will later be screwed in place from the front and attach thermodisc cage to bracket on the underside of the firebox 5 Push power cord and ground wire towards front of unit Connect two ...

Страница 74: ...m 8 Diagram 9 Fan Install After Unit Installation The The fan may be installed after the unit has been installed and finished Ensure the unit is turned off and has cooled to room temperature 1 Remove the screen glass door and bottom cover panel see manual for instructions 2 Remove any media already installed logs glass etc and set aside 3 Remove the log grate if installed 4 Remove the burner by re...

Страница 75: ...e replaced by a wall mounted fan speed control WALL CONTROL KIT MUST BE INSTALLED DURING UNIT INSTALLATION STAGE 2 Remove the fan speed control module from the fan kit by breaking the connection of the wires at the connectors shown below Dis card the fan speed control module 3 Reconnect the wires at connectors where the fan speed control module was previously located by using the supplied connecto...

Страница 76: ...lack wire from the clip 4 Break the connection between the inline wire connectors on the black wire 5 Connect the two connectors on the black wire to the two wires from the remote receiver as shown 6 Put the receiver in position in the holder bracket beneath the firebox to the right of the DC Sparker and Fan Speed Control Module if installed Secure with supplied velcro strips 7 Tidy the wires toge...

Страница 77: ...llation Glass Door Removal 1 To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up and ou...

Страница 78: ... cleaning NOTE When the glass is cold and the appliance is lit it may cause con densation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE First Fire Normal Operating Sounds of Gas Appliances It is possible that you will hear some sound...

Страница 79: ...es ensuring they are the correct polarity 5 Reinstall battery compartment door 1 Remove screen See instructions in this manual on screen removal 2 Locate DC sparker box see diagram 2 located on right hand side of the gas valve 3 Install the supplied AA alkaline battery into the DC sparker box by opening the battery compartment door NOTE The AA battery in the DC sparker box will need to be replaced...

Страница 80: ...and to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part of the control syste...

Страница 81: ...urner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily dam aged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3 ...

Страница 82: ...ram 3 Diagram 3 Switch wires Diagram 6 Replace Thermocouple 1 Follow steps 1 13 for replacing valve 2 Disconnect thermocouple at gas valve 3 Disconnect thermocouple at pilot assembly end 4 Replace thermocouple 5 Reverse steps 1 13 6 Remove lower brick or enamel panel 7 Slidetheburnerassemblytotherighttorelease it from the orifice then lift it out 10 Disconnect the two switch wires from the valve a...

Страница 83: ...Grandview G800C Gas Fireplace 83 parts list Main Assembly ...

Страница 84: ...ifice Mnt 10 BZ001 9 Part Description N S 656 039 Gasket Orifice Mount N S 905 037 Inlet Flex Line Gas SS Steel 3 8 ODX 12 inch N S 910 074 Spark Generator Switch Comes With Wire N S 910 369 Receptacle Box Low Volt SC100A N S 910 576 Cover Wall Mount White GTM SIT 0 584 803 N S 910 428 Receptacle Duplex White N S 910 430 Receptacle Cover Duplex Metal N S 904 687 Connector Clamp 3 8 CI 804 N S 911 ...

Страница 85: ...r Panel Black Enamel N S 761 922 Faceplate Brush Nickel N S 761 924 Faceplate Mt Black N S 761 926 Faceplate Brush Antique Copper N S 761 928 Trim Finishing Black 3 Sided N S 761 929 Trim Finishing Clean Front Black 3 Sided N S 761 930 Log Set Complete Oak N S 761 932 Log Set Complete Birch N S 761 938 Log Grate Ember Package N S 761 941 Chase Vent White N S 761 974 Fan Wall Control N S 761 976 Re...

Страница 86: ...oards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled c...

Страница 87: ...stallation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance ...

Страница 88: ... should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief des...

Страница 89: ...er for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in ...

Страница 90: ...90 Grandview G800C Gas Fireplace notes ...

Страница 91: ...Grandview G800C Gas Fireplace 91 notes ...

Страница 92: ..._____________________________ Phone ______________________________________________________ Date Installed _________________________________________________ Serial No _____________________________________________________ Printed in Canada Regency Grandview Surefire and AstroCap are trademarks of FPI Fireplace Products International Ltd Copyright 2019 FPI Fireplace Products International Ltd All rig...