installation
AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)
An AC power adaptor MUST be installed as a constant power source for the SureFire system.
IMPORTANT: Do not use the 4-AA batteries in the SureFire receiver.
INSTALL AC ADAPTOR WITH SUREFIRE WALL SWITCH/WALL THERMOSTAT ONLY - (WITHOUT REMOTE)
INSTALL AC ADAPTOR WITH SUREFIRE PROFLAME REMOTE
1. Locate “DC Supply” tag on wire harness (located in the unit).
2. Connect the male end from AC adaptor to the female end
tagged “DC Supply” on wiring harness in unit.
2. Locate FCM - COM connector labeled on the Remote wire harness.
3. Attach female end of DC supply wire (red/black) from valve wiring
harness located on unit to the male FCM-COM supply wire (red/black)
from remote control wiring harness - be careful not to damage ends.
This only fits one way. Do Not Force in wrong way.
3. Plug AC adaptor into 120V power cord located inside the gas fireplace
firebox).
4. Neatly tuck any loose AC Power Adaptor wires underneath / inside
the appliance.
Note: Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
FCM - COM
AC adaptor
wire adaptor
1. Connect the male end of the AC adaptor (from unit) to the female end
of the wire adaptor (supplied with optional remote) together as shown.
AC adaptor
Wire adaptor
FCM - COM
4. Plug AC adaptor into 120V wall outlet (or into 120V power cord located
inside the gas fireplace firebox).
5. Neatly tuck any loose AC Power Adaptor wires underneath / inside
the appliance.
Note:
This should only be plugged in when unit is fully installed and
ready for use.
Note:
Ensure that wires do not touch the underside of the firebox (keep
wires away from the heat as much as possible).