10 |
Regency
®
E18E-11 Gas Fireplace Insert
owner's information
17. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
18. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
19. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the electrical control system
and any gas control which has been under water.
20.
WARNING: Failure to position the
parts in accordance with the diagrams
in this manual or failure to use only
parts specifically approved with this
appliance may result in property
damage or personal injury.
21.
WARNING: Operation of this appliance
when not connected to a properly
installed and maintained venting
system or tampering with the blocked
vent shut-off system can result in
carbon monoxide (CO) poisoning and
possible death.
22. All original vent systems must be inspected for
carbon/soot build up prior to installation of the
E18E. The installer should also ensure prior
to installation that the existing vent system is
adequate for the rated input of this appliance
(21,600 BTU NG/20,500 BTU LP).
Signs of white buildup (aldehydes) in the vent
system would indicate that the appliance was
not drafting properly due to vent height, diameter
of vent, excessive offsets, negative pressure,
kinks, etc.
Adhere to the local gas code within your
jurisdiction for vent sizing.
Any venting system that causes the Regency
E18E to not function as it should is not the
responsibility of the manufacturer.
Содержание Energy E18E
Страница 102: ...102 Regency E18E 11 Gas Fireplace Insert warranty ...