ZERO CLEARANCE FRAMING
ZERO CLEARANCE INSTALLATION
When installing the E18E as a zero clearance, you will use the
framing clearances in the following diagrams. Mantel and inside corner
clearances can be found in Minimum Clearances to Combustibles.
,QQHUER[
2XWHUER[
1. When framing is complete, ensure wiring is installed by an electrician
prior to installing the unit.
2. Assemble ZC surround with 8 (904-897) screws provided in locations
shown below.
3. Secure surround to the stud on each side with wood screws (not sup-
plied).
Assemble the ZC
surround with 4
screws on each
side.
Use 4 screws on each side to secure
surround to studs.