10
|
Regency
®
E21-10 Gas Fireplace Insert
|
10
installation
MINIMUM FIREPLACE
CLEARANCES
Diagram shows the minimum fireplace opening
required to be able to install the Regency
®
gas
fireplace insert.
INSTALLATION
CHECKLIST
1)
Locate your appliance. Refer to the "Clear
-
ances to Combustibles" and "Minimum
Fireplace Clearances" sections.
A
B
C
2)
Make gas and electrical connections. Refer to
the "Gas Connection" section.
Test the pilot. Must be as per diagram in the
"Valve Description" section.
3)
Install Flue Connector. Refer to the "Flue Con
-
nector Installation" section.
4)
Install vent. Refer to the "Venting" section.
5)
Test Gas pressure. Refer to the "Gas Pipe
Pressure Testing" section.
Check aeration. Refer to the "Gas Insert Aera
-
tion System" section.
6)
Test for flue spillage. Refer to the "Test for Flue
Spillage" section.
7)
Install 4AA batteries into receiver. Hook receiver
to wire marked receiver, this will enable opera
-
tion of the appliance manually when position in
"ON" position.
8)
Install standard and optional features. Refer
to the following sections where applicable:
a. Brick Panel
b. Faceplate
c. Flush Glass Door
d. Remote Control
9)
Install 1-AA battery into DC spark box, located
on bottom right side of unit.
10)
Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1)
Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2)
If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
3)
Ensure that the appliance is venting correctly.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam
-
age is not the responsibility of the manufacturer.
Max Lentil Bar
Depth
A
Height
B
Depth
C
Width
(rear)
D
Width
(front)
E
Width
F
Front Depth
To Taper
G
Low
Profile
Faceplate
11-1/2"
18-1/2"
14-3/8"
18"
28-3/8"" 28-3/4"
3/4"
Low Profile
Faceplate
w/Spacer
10-1/8"
17-3/4"
13-1/8"
18"
N/A
26-1/2"
N/A
13-1/8” (333mm)
Low prole faceplate
w/spacer
14-3/8"(365mm)
with spacer
Содержание E21-LP10
Страница 32: ...32 Regency E21 10 Gas Fireplace Insert 32 notes ...
Страница 33: ...Regency E21 10 Gas Fireplace Insert 33 33 notes ...