installation
TEST FOR
FLUE SPILLAGE
A " spillage" test must be made before
the installed unit is left with the customer.
Follow the procedure below:
1)
Close all external doors and windows in
the house.
2)
Light the unit and set controls to maximum.
Turn fan to OFF on unit.
3)
After five minutes, test that there is a “pull”
on the flue by placing a smoking match,
cigarette or similar device which gives off
smoke, in front of the upper part of the glass
door. To ensure a valid test, place
GAS INSERT AERATION
SYSTEM
The aeration adjustment rod is attached to the
air shutter which is located just above the orifice
bracket. The rod is used to adjust the aeration
on the main burner without having to take the
appliance apart.
The burner aeration is factory set but may need
adjusting due to either the local gas supply, air
supply or altitude.
Natural Gas: 1/8" open
Propane:
5/16" open
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only be
performed by an authorized Regency
®
Installer at the time of installation or
service.
a scrap piece of sheet metal (or other
noncombustible material) in the space
between the glass door and faceplate, this
will prevent the natural convection of the
unit from interfering with the test.
Note: The smoke should be drawn into the
spill tube. If the smoke is still not
drawn in, turn the unit off and check
for the cause of the lack of draft. If
necessary, seek expert advice.
OPTIONAL
BRICK PANEL
1)
Unwrap the brick pattern panels from the
protective wrapping.
2)
With the glass removed, position the
back panel first (see diagram for correct
positioning), then the two side panels. Slide
the side brick panel into place from the front
of the firebox, there is a tab at the top of the
unit to hold the side panels in place.
3)
The brick panels should be tight against
the firebox sides and back. The side panels
should be flush with the glass.
Note: Use caution when sliding side panels
in as they can easily be scratched by
the brick panel tabs.
SIT 829 VALVE DESCRIPTION
1)
Gas on/off knob
2)
Electronically Operated Hi/Lo
3)
Pilot Adjustment
4)
Thermocouple Connection -
option
5)
Outlet Pressure Tap
6)
Inlet Pressure Tap
7)
Pilot Outlet
8)
Main Gas Outlet
9)
Alternative TC Connection Point
Install the supplied battery into the DC Sparker Box
by opening the battery compartment.
NOTE:
The battery in the DC Sparker Box will
need to be replaced annually.
DC SPARK IGNITER
BATTERY INSTALLATION