background image

 

 Regency

®

 E21-10 Gas Fireplace Insert

  |     

35

 

 

|

 

35

warranty

Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thorough-
ly before it leaves our facility.  Regency® Fireplace Products is pleased to extend this limited lifetime warranty to the  original purchaser of a Regency® Product. This 
warranty is not transferable.

The Warranty: Limited Lifetime: 

The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, glass beads,ceramic spa stones, pebbles, brick panels and gold plating (against defective manufac-
ture only) are covered under the Limited Lifetime Warranty for five (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of 
purchase and parts only thereafter.

Special Finishes - One year on stainless steel panels, enamel panels, Verona glass surrounds, stainless steel inner/outer door frames, inlays, nickel overlays, nickel faceplates, 
brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. Regency® warranties the 
product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, i.e.. finger prints, etc. applied after the 
purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, fan motors, switches, wiring, thermodiscs, Regency

®

 remote controls, spill switches, thermopiles, thermocouples, pilot assem-

bly, Flame sensors, electrodes, fan control modules, IFC/DFC fireplace controls, AC adaptors, and gas valves are covered for two years parts and one year subsidized labour* from 
the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance. i.e. twelve (12) months from original purchase date of 
appliance with a minimum of three (3) months coverage from date of replacement.

Regency

®

 venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. Warranty.

Repair/replacement parts purchased by the consumer from Regency

®

 after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item 

shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid-
ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of instal-
lation. Reported damage after this time will be subject to rejection.

It is the general practice of Regency

®

 to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency® and evalu-

ated for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Regency

®

 product. Regency

®

 will not be liable for results or costs of workmanship from 

unauthorized service persons or dealers. 

At all times Regency

®

 reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to Regency

®

 by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, pur-

chase date, serial #, type of unit, problem, and part or parts requested, a copy of the bill of sale/proof of purchase must also accompany any submitted claims, without this information 
the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, batteries, volcanic stones, lava embers, rockwool, door handles, platinum embers, embaglow embers, door or glass 
gasketing or trim.

At no time will Regency

®

 be liable for any consequential damages which exceed the purchase price of the unit. Regency

®

 has no obligation to enhance or modify any unit once manu-

factured. i.e.. as products evolve, field modifications or upgrades will not be performed.

Regency

®

 will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence or 
accident, spillage or down drafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems 
such as furnaces, fans, clothes dryer, etc.

It is the responsibility of the home owner to service and maintain the appliance. If any claims are sent to FPI, you may be asked for service records to ensure the appliance has been 
maintained. Retain all receipts for both service and/or parts which may have been replaced. Lack of service/maintenance is the largest contributor to malfunction of an appliance and 
is not covered under the terms of this warranty.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

Regency

®

 will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from  Regency

®

, may nullify your warranty 

on this product.

Malfunction/damage of this appliance due to mother nature (wind, rain, snow, floods, etc.) is not covered under the terms of this warranty policy. Some minor expansion, contraction, 
or movement of certain parts and resulting noise, is normal and not a defect and therefore not covered under this Limited Warranty.
If the appliance has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, it will not be covered under this Limited Warranty.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior/exterior facia is not the responsibility of Regency

®

.

Subsidy according to job scale as predetermined by FPI.

Gas Product Warranty 2015

Содержание E21-LP10

Страница 1: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier...

Страница 2: ...ith all the warmth and charm of a fireplace at the flick of a switch The models E21 NG10 and E21 LP10 of this series have been approved by Warnock Hersey Intertek for safety As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of yo...

Страница 3: ...ion 36 40 3 16 22 7 8 20 1 4 28 3 16 1 2 11 1 2 14 1 4 17 5 8 715mm 913mm 362mm 396mm 291mm 13mm 578mm 1020mm 514mm 442mm 17 7 16 24 7 8 631mm 9 11 16 244mm 2 1 4 56mm Shown with Low Profile Faceplate Oversize Faceplate Dimensions 44 1 8 W x 25 3 4 H ...

Страница 4: ...ation 16 Gas Insert Aeration system 16 Test for Flue Spillage 16 Optional Brick Panel 16 Log Set Installation 17 Flush Glass installation 21 Safety screen installation removal 21 Conversion from NG to LP 22 Low profile faceplate installation 23 Optional backing plate installation 25 Wall Thermostat 25 Final Check 26 Operating Instructions 26 First Fire 26 Automatic Convection Fan Operation 26 Norm...

Страница 5: ...SBCS A225 1 NFPA 501A Manufactured doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil peut être le permettent Voir la notice de l utilisateur pour plus de renseignements Cet appareil ne peut pas être ut AVERTISSEMENT Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut ê remplacées et que le foyer ait été approuvé de nou...

Страница 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 7: ...PT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHEN THEY ARE INTHESAMEAREAASTHEAPPLIANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLETO AC CIDENTAL CONTACT BURNS...

Страница 8: ...tallation into a mobile home 9 Inspect the venting system annually for block age and any signs of deterioration 10 Any safety glass removed for servicing must be replaced prior to operating the appliance 11 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace insert 12 Wear gloves and safety glasses for protection while doing required maintenance 13 Ensure adequ...

Страница 9: ... solidfuelsunlessalloriginalpartshavebeen replaced and the fireplace re approved by the authority having jurisdiction FACTORY BUILT METAL WOOD BURNING FIREPLACE REQUIREMENTS NOTE Anypartsthatareremovedmustberemoved in a way that would allow them to be re installed if the insert is ever removed removal of rivets or screws is acceptable To reference parts see illustration below Must be removed 1 Dam...

Страница 10: ... standard and optional features Refer to the following sections where applicable a Brick Panel b Faceplate c Flush Glass Door d Remote Control 9 Install 1 AA battery into DC spark box located on bottom right side of unit 10 Final check Refer to the Final Check section Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully exp...

Страница 11: ...e appliance to a combustible side wall is 9 inches 229mm The minimum clearance from the top of the appliance to a combustible mantel is 14 inches 356mm The minimum height from the top of the appliance to the ceiling is 36 inches 914mm Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board ...

Страница 12: ...sult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approvedfittings Alwaysprovideaunionsothat gas lines can be easily disconnected for burner or fan servicing Flare nuts for copper lines and flex connectors are usually considered to meet ...

Страница 13: ...eeded for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges When connected with 120 volts the appliance must be electrically grounded in accordance with local codes or in the absence of local codes the current CSA C22 1 in Canada or with the National Electrical Code ANSI NFPA 70 1987 in USA NOTE This unit is equipped with a heat sens...

Страница 14: ...e to the flue collar with three sheet metal screws 3 Place the appliance on the hearth Push the appliance into the fireplace and at the same time slide the plate back onto the appliance 4 Replace the screw holding the plate just before completely pushing the appliance into the fireplace OFFSET FLUE ADAPTOR AnOffsetFlueAdaptorKit Part 532 920isavailable as an accessory to move the flue outlet back ...

Страница 15: ...t venting charts and local code requirements The Regency Insert incorporates its own internal draft hood so no additional external draft hood is required Check periodically that the vent is unre stricted and an adequate draft is present when the unit is in operation Before installing the vent system ensure that the damper plate is locked into the open position and secure to prevent the damper plat...

Страница 16: ... of sheet metal or other noncombustible material in the space between the glass door and faceplate this will prevent the natural convection of the unit from interfering with the test Note The smoke should be drawn into the spill tube If the smoke is still not drawn in turn the unit off and check for the cause of the lack of draft If necessary seek expert advice OPTIONAL BRICK PANEL 1 Unwrap the br...

Страница 17: ...7 28 27 24 27 25 27 27 27 29 27 30 27 23 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Spread vermiculite around the firebox base Then take some embers and spread them over the vermiculite as shown 3 Fit log 27 23 into the pins on the back log tray 4 Fit log 27 24 into the pins on the middle right hand side of the burner...

Страница 18: ...nt right side of the burner 5 Rest the top of log 27 25 in the notch in log 27 24 and rest the bottom end of log 27 25 on the firebox base 7 Fit the top end of log 27 27 into the pin in log 27 23 and rest the bottom end of log 27 27 against the 2nd grate post 2nd Grate Post 27 24 27 25 27 25 27 26 27 26 27 27 27 23 27 27 ...

Страница 19: ...log 27 29 into the pin on the front left side of the burner in front of the 1st grate post and rest the right end of log 27 29 onto the notch on log 27 27 1st Grate Post 10 Fit the top of log 27 30 into the pin on the right side of log 27 23 and rest the bottom of the log on the notches in logs 27 26 and 27 24 27 28 27 29 27 27 27 29 27 23 27 30 27 26 27 24 Notch ...

Страница 20: ...ong the front of the burner as shown Ensure not to cover any burner ports 27 25 27 28 27 24 27 26 27 29 27 27 27 30 12 Place rock wool along side the embers on the front of the burner as shown Ensure not to cover any burner ports 13 Separate platinum embers and place on the burner just in front of the logs Avoid stacking platinum embers ...

Страница 21: ... product warranties Do not operate the appliance if the glass panel s are removed cracked or broken Replacement of the glass panel s should be done by a qualified service person SAFETY SCREEN INSTALLATION REMOVAL 1 To install the safety screen assembly onto the unit lift assembly up and lower tabs on safety screen onto pins inside unit as shown below 2 Lower screen assembly onto unit bottom of scr...

Страница 22: ...h to hold onto the elbow behind the orifice Replace with the 54 orifice in the Kit 10 Remove NG stepper motor by removing 3 screws in locations shown below re place with LP stepper motor secure in place with 3 screws Remove NG Stepper motor and replace with LP Stepper motor 12 Check for gas leaks with a proper soapy solution or leak detector 13 Check for proper spark between the ignitor and pilot ...

Страница 23: ... black and red fan switch wires in the black casing to the wire connectors from the fan speed control 5 Secure the wires to the back of the inner faceplate with a wire clip 6 Ensure batteries are installed into receiver then Install receiver packed with manual on the right side of the faceplate backing connect 12 pin connector to receiver from wiring harness marked receiver 3 Tuck the wires into t...

Страница 24: ...nit as shown below Final Install Pin in unit Tab on screen assembly Magnet at bottom of screen 12 Line up the brackets on the outer faceplate with the slots on the faceplate backing hook outer faceplate on to slots and lower to install Diagram 10 11 Lower screen assembly onto unit bottom of screen is secured by 2 magnets 8 Attach the bottom louver to the 2 hinges using 2 screws per hinge Diagram 9...

Страница 25: ...sembled Faceplate Backer spacer backside Spacer Backing Plate Backing Plate backside Backing plate installation with spacer Backing plate installation without spacer 1 Install the spacer to the back of the faceplate backing with 6 screws from the front of the faceplate backing 2 screws are also required to secure the top section of the spacer only 3 Proceed to faceplate installation see faceplate ...

Страница 26: ...auge material from the rest of the firebox and body Therefore thevaryingthicknessesofsteelwill expand and contract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turn...

Страница 27: ... the pilot is lit Release knob 3 Push in gas control knob slightly and turn to ON position 4 Ensure the receiver is in the remote position IMPORTANT Prior to igniting or re igniting the pilot remove the glass door Set Switch to Remote 5 Press and release the ON OFF button on the remote handheld transmitter An audible beep should be heard from the receiver ON OFF Button 6 The unit will turn on SHUT...

Страница 28: ...qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l eau DO NOT REMOVE THIS INSTRUCTION PLATE TO TURN OFF GAS APPLIANCE This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 CAUTION Hot while in operation Do not to...

Страница 29: ...then pull the thermosdisc out of the bracket 11 Remove the 2 screws on each side of the firebox bottom and 4 screws on the rear wall and lift out LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacemen...

Страница 30: ...d Slide Plate 12 910 343 Spill Switch 13 532 013 Spill Switch Bracket 17 532 012 Baffle 23 Bottom Flush Louver 24 535 006 Inner Trim 25 535 008 Safety Screen 26 535 007 Screen Frame 532 901 Brick Panel Set Standard Brown 532 902 Brick Panel Set Standard Red 532 903 Brick Panel Set Herringbone Brown 33 Brick Panel Rear 34 Brick Panel Left Side 35 Brick Panel Right Side 36 400 090 Brick Clips 39 530...

Страница 31: ... 386 Thermocouple 61 402 526 Grate Diffuse Assembly 62 533 535 Burner Assembly NG LP 910 096 Pilot Hood 3 Way 910 432 Pilot Tube w Nut 911 137 Pilot Hood Clip 910 592 Remote Transmitter GTMF 911 164 Valve Remote Wiring Harness 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 533 930 Complete Log Set 535 969 Conversion to Propane Kit Not available as a replacement part LOW PROFILE FACEPLATE ASSEMB...

Страница 32: ...32 Regency E21 10 Gas Fireplace Insert 32 notes ...

Страница 33: ...Regency E21 10 Gas Fireplace Insert 33 33 notes ...

Страница 34: ...34 Regency E21 10 Gas Fireplace Insert 34 notes ...

Страница 35: ...ent parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product Regency will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times Regency reserves the right to inspect product...

Страница 36: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all...