requirements

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 

residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 

seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 

be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 

equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 

installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 

operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 

served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 

qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 

monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 

thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 

monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 

shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 

sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 

unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 

5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 

the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 

structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 

Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 

instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 

Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 

"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 

detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 

all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 

the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Содержание E21-LP10

Страница 1: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier...

Страница 2: ...ith all the warmth and charm of a fireplace at the flick of a switch The models E21 NG10 and E21 LP10 of this series have been approved by Warnock Hersey Intertek for safety As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of yo...

Страница 3: ...ion 36 40 3 16 22 7 8 20 1 4 28 3 16 1 2 11 1 2 14 1 4 17 5 8 715mm 913mm 362mm 396mm 291mm 13mm 578mm 1020mm 514mm 442mm 17 7 16 24 7 8 631mm 9 11 16 244mm 2 1 4 56mm Shown with Low Profile Faceplate Oversize Faceplate Dimensions 44 1 8 W x 25 3 4 H ...

Страница 4: ...ation 16 Gas Insert Aeration system 16 Test for Flue Spillage 16 Optional Brick Panel 16 Log Set Installation 17 Flush Glass installation 21 Safety screen installation removal 21 Conversion from NG to LP 22 Low profile faceplate installation 23 Optional backing plate installation 25 Wall Thermostat 25 Final Check 26 Operating Instructions 26 First Fire 26 Automatic Convection Fan Operation 26 Norm...

Страница 5: ...SBCS A225 1 NFPA 501A Manufactured doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil peut être le permettent Voir la notice de l utilisateur pour plus de renseignements Cet appareil ne peut pas être ut AVERTISSEMENT Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut ê remplacées et que le foyer ait été approuvé de nou...

Страница 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 7: ...PT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHEN THEY ARE INTHESAMEAREAASTHEAPPLIANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLETO AC CIDENTAL CONTACT BURNS...

Страница 8: ...tallation into a mobile home 9 Inspect the venting system annually for block age and any signs of deterioration 10 Any safety glass removed for servicing must be replaced prior to operating the appliance 11 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace insert 12 Wear gloves and safety glasses for protection while doing required maintenance 13 Ensure adequ...

Страница 9: ... solidfuelsunlessalloriginalpartshavebeen replaced and the fireplace re approved by the authority having jurisdiction FACTORY BUILT METAL WOOD BURNING FIREPLACE REQUIREMENTS NOTE Anypartsthatareremovedmustberemoved in a way that would allow them to be re installed if the insert is ever removed removal of rivets or screws is acceptable To reference parts see illustration below Must be removed 1 Dam...

Страница 10: ... standard and optional features Refer to the following sections where applicable a Brick Panel b Faceplate c Flush Glass Door d Remote Control 9 Install 1 AA battery into DC spark box located on bottom right side of unit 10 Final check Refer to the Final Check section Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully exp...

Страница 11: ...e appliance to a combustible side wall is 9 inches 229mm The minimum clearance from the top of the appliance to a combustible mantel is 14 inches 356mm The minimum height from the top of the appliance to the ceiling is 36 inches 914mm Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board ...

Страница 12: ...sult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approvedfittings Alwaysprovideaunionsothat gas lines can be easily disconnected for burner or fan servicing Flare nuts for copper lines and flex connectors are usually considered to meet ...

Страница 13: ...eeded for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges When connected with 120 volts the appliance must be electrically grounded in accordance with local codes or in the absence of local codes the current CSA C22 1 in Canada or with the National Electrical Code ANSI NFPA 70 1987 in USA NOTE This unit is equipped with a heat sens...

Страница 14: ...e to the flue collar with three sheet metal screws 3 Place the appliance on the hearth Push the appliance into the fireplace and at the same time slide the plate back onto the appliance 4 Replace the screw holding the plate just before completely pushing the appliance into the fireplace OFFSET FLUE ADAPTOR AnOffsetFlueAdaptorKit Part 532 920isavailable as an accessory to move the flue outlet back ...

Страница 15: ...t venting charts and local code requirements The Regency Insert incorporates its own internal draft hood so no additional external draft hood is required Check periodically that the vent is unre stricted and an adequate draft is present when the unit is in operation Before installing the vent system ensure that the damper plate is locked into the open position and secure to prevent the damper plat...

Страница 16: ... of sheet metal or other noncombustible material in the space between the glass door and faceplate this will prevent the natural convection of the unit from interfering with the test Note The smoke should be drawn into the spill tube If the smoke is still not drawn in turn the unit off and check for the cause of the lack of draft If necessary seek expert advice OPTIONAL BRICK PANEL 1 Unwrap the br...

Страница 17: ...7 28 27 24 27 25 27 27 27 29 27 30 27 23 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Spread vermiculite around the firebox base Then take some embers and spread them over the vermiculite as shown 3 Fit log 27 23 into the pins on the back log tray 4 Fit log 27 24 into the pins on the middle right hand side of the burner...

Страница 18: ...nt right side of the burner 5 Rest the top of log 27 25 in the notch in log 27 24 and rest the bottom end of log 27 25 on the firebox base 7 Fit the top end of log 27 27 into the pin in log 27 23 and rest the bottom end of log 27 27 against the 2nd grate post 2nd Grate Post 27 24 27 25 27 25 27 26 27 26 27 27 27 23 27 27 ...

Страница 19: ...log 27 29 into the pin on the front left side of the burner in front of the 1st grate post and rest the right end of log 27 29 onto the notch on log 27 27 1st Grate Post 10 Fit the top of log 27 30 into the pin on the right side of log 27 23 and rest the bottom of the log on the notches in logs 27 26 and 27 24 27 28 27 29 27 27 27 29 27 23 27 30 27 26 27 24 Notch ...

Страница 20: ...ong the front of the burner as shown Ensure not to cover any burner ports 27 25 27 28 27 24 27 26 27 29 27 27 27 30 12 Place rock wool along side the embers on the front of the burner as shown Ensure not to cover any burner ports 13 Separate platinum embers and place on the burner just in front of the logs Avoid stacking platinum embers ...

Страница 21: ... product warranties Do not operate the appliance if the glass panel s are removed cracked or broken Replacement of the glass panel s should be done by a qualified service person SAFETY SCREEN INSTALLATION REMOVAL 1 To install the safety screen assembly onto the unit lift assembly up and lower tabs on safety screen onto pins inside unit as shown below 2 Lower screen assembly onto unit bottom of scr...

Страница 22: ...h to hold onto the elbow behind the orifice Replace with the 54 orifice in the Kit 10 Remove NG stepper motor by removing 3 screws in locations shown below re place with LP stepper motor secure in place with 3 screws Remove NG Stepper motor and replace with LP Stepper motor 12 Check for gas leaks with a proper soapy solution or leak detector 13 Check for proper spark between the ignitor and pilot ...

Страница 23: ... black and red fan switch wires in the black casing to the wire connectors from the fan speed control 5 Secure the wires to the back of the inner faceplate with a wire clip 6 Ensure batteries are installed into receiver then Install receiver packed with manual on the right side of the faceplate backing connect 12 pin connector to receiver from wiring harness marked receiver 3 Tuck the wires into t...

Страница 24: ...nit as shown below Final Install Pin in unit Tab on screen assembly Magnet at bottom of screen 12 Line up the brackets on the outer faceplate with the slots on the faceplate backing hook outer faceplate on to slots and lower to install Diagram 10 11 Lower screen assembly onto unit bottom of screen is secured by 2 magnets 8 Attach the bottom louver to the 2 hinges using 2 screws per hinge Diagram 9...

Страница 25: ...sembled Faceplate Backer spacer backside Spacer Backing Plate Backing Plate backside Backing plate installation with spacer Backing plate installation without spacer 1 Install the spacer to the back of the faceplate backing with 6 screws from the front of the faceplate backing 2 screws are also required to secure the top section of the spacer only 3 Proceed to faceplate installation see faceplate ...

Страница 26: ...auge material from the rest of the firebox and body Therefore thevaryingthicknessesofsteelwill expand and contract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turn...

Страница 27: ... the pilot is lit Release knob 3 Push in gas control knob slightly and turn to ON position 4 Ensure the receiver is in the remote position IMPORTANT Prior to igniting or re igniting the pilot remove the glass door Set Switch to Remote 5 Press and release the ON OFF button on the remote handheld transmitter An audible beep should be heard from the receiver ON OFF Button 6 The unit will turn on SHUT...

Страница 28: ...qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l eau DO NOT REMOVE THIS INSTRUCTION PLATE TO TURN OFF GAS APPLIANCE This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 CAUTION Hot while in operation Do not to...

Страница 29: ...then pull the thermosdisc out of the bracket 11 Remove the 2 screws on each side of the firebox bottom and 4 screws on the rear wall and lift out LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacemen...

Страница 30: ...d Slide Plate 12 910 343 Spill Switch 13 532 013 Spill Switch Bracket 17 532 012 Baffle 23 Bottom Flush Louver 24 535 006 Inner Trim 25 535 008 Safety Screen 26 535 007 Screen Frame 532 901 Brick Panel Set Standard Brown 532 902 Brick Panel Set Standard Red 532 903 Brick Panel Set Herringbone Brown 33 Brick Panel Rear 34 Brick Panel Left Side 35 Brick Panel Right Side 36 400 090 Brick Clips 39 530...

Страница 31: ... 386 Thermocouple 61 402 526 Grate Diffuse Assembly 62 533 535 Burner Assembly NG LP 910 096 Pilot Hood 3 Way 910 432 Pilot Tube w Nut 911 137 Pilot Hood Clip 910 592 Remote Transmitter GTMF 911 164 Valve Remote Wiring Harness 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 533 930 Complete Log Set 535 969 Conversion to Propane Kit Not available as a replacement part LOW PROFILE FACEPLATE ASSEMB...

Страница 32: ...32 Regency E21 10 Gas Fireplace Insert 32 notes ...

Страница 33: ...Regency E21 10 Gas Fireplace Insert 33 33 notes ...

Страница 34: ...34 Regency E21 10 Gas Fireplace Insert 34 notes ...

Страница 35: ...ent parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product Regency will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times Regency reserves the right to inspect product...

Страница 36: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all...

Отзывы: