installation
CLEARANCES TO COMBUSTIBLES
*31-1/2"
To base
of unit
* With mantel at 0" to 3-1/2"
The minimum clearance from the side of the appliance to a combustible
side wall is 9 inches (229mm). The minimum clearance from the top of the
appliance to a combustible mantel is
14 inches (356mm). The minimum
height from the top of the appliance to the ceiling is
36 inches (914mm)
.
Note: A non-combustible mantel may be installed at a lower height
if the framing is made of metal studs covered with a non-
combustible board.