background image

City Series

®

 

Zero Clearance Direct Vent Gas Fireplace

Owners & 

Installation Manual

STYLE

 

                     

     MODEL 

   

Single sided                            CV40E-NG11 / CV40E-LP11                          

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     Warning
Fire or explosion Hazard

failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

919-927d

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

09.25.20

San Francisco Bay 

CB40E-NG1

Installation video

http://bit.ly/2vjpzmr

Installer

: Please complete the details on the back cover and leave this 

manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

Certified to/Certifié pour: CSA 2.17-2017
                                            ANSI Z21.88-2017
                                            CSA 2.33-2017

Tested by : 

Содержание CB40E-LP11

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property damage 919 927d FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 ...

Страница 2: ...ontrol transmitter from on to off and back to on Once the pilot has re established operation will resume as normal There is no requirement to do anything with the IPI CPI mode on the remote control transmitter If the unit never goes as long as seven full days without a call for heat the pilot will remain lit until it is manually shut off If the unit is being operated in IPI intermittent pilot mode...

Страница 3: ...urer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped wit...

Страница 4: ...placement 17 Warranty 80 Vertical terminations 42 Venting Arrangement for Vertical Terminations 43 Vertical Terminations Rigid Pipe 4 x 6 5 8 44 Unit Installation with Horizontal Termination 45 Unit Installation with Horizontal Termination 46 Dura Vent Horizontal Terminations 47 Dura Vent Vertical Termination 48 Vertical Termination 4 x 6 7 8 Venting Vertical Flex Vent Kit 946 755 49 Vertical Flue...

Страница 5: ...s and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard orANSI A119 2 ou NFPA501C Standard ...

Страница 6: ...m CV40E Dimensions Note Height Dimension may vary depending on the height of the leveling legs Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ON...

Страница 7: ...IVIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS City Line Direct Vent Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensu...

Страница 8: ...o operating the appliance 7 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace 8 Wear gloves and safety glasses for protection while doing required maintenance 9 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 10 Under no circumstances should this appliance be modified Parts that have to be removed for servicing...

Страница 9: ...stem will spark for 60 seconds to light the pilot 4 The unit will turn on Lighting Procedure Continuous Pilot Intermittent Pilot CPI IPI selection See remote control instructions for details On Demand Pilot seven day safety timer Important information if using the appliance in CPI continuous pilot mode only This appliance is a ProFlame 2 system fitted with the On Demand Pilot a safety feature whic...

Страница 10: ...tment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un incendie ou une explosion pouvant ...

Страница 11: ...roflame Transmitter Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batterie...

Страница 12: ... by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The ...

Страница 13: ... The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To act...

Страница 14: ...inuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a traditional continuous pilot The primary benefit of having the ...

Страница 15: ...s handling will not be covered under warranty We recommend handling the glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner prior to operating the appliance Note glass panel...

Страница 16: ...HANDLING We recommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty We recommend handling the glass with supplied v...

Страница 17: ... before cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brushasthelogsarefragileandeasilydamaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner ...

Страница 18: ...y in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection...

Страница 19: ...ances section for details 6 We recommend that you plan your installa tion on paper using exact measurements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to Exterior Vent Termination Locations section Unit Assembly Prior to Installation Before you ...

Страница 20: ...side that can be adjusted if required Access Panel Removal The front access panel may be removed for ease of hooking up gas and electrical Once complete ensure that the access panel is reinstalled prior to any finishing The CV40E has 4 screws to remove access cover See locations in diagrams to the right 4 screws ...

Страница 21: ...g envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 4 Inspecttheventingsystemannuallyforblockage and any signs of deterioration 5 Venting terminals shall not be recessed into a wall or siding 6 Any safety glass removed for servicing must be replaced prior to operating the appliance 7 To prevent injury do not allow anyone who is u...

Страница 22: ...g B2 Opening Height 15 1 16 383mm Bottom Top of Fireplace Opening C Sidewall on one side 8 1 2 216mm Side of Fireplace Opening D Mantel Depth max E Alcove Width 84 2134mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to Unit Maximum G Ceiling in front of fireplace 37 1 2 953mm Top of Fireplace Opening H Convection Air Outlet Top of Enclosure J Convection Air Outlet Opening Offset 0 3 ...

Страница 23: ...n the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 2 12 6 4 8 10 0 14 9 229 m 15 1 16 383 mm 10 20 26 Top of Fireplace Opening 12 305 mm 1 2 13 mm Drywall wood wood panel etc 5 1 8 384 mm To Bottomof Fireplace Opening 12 4 Allowable mantel MANTEL LEG leg projection 7 8 1 2 2 CV40E ...

Страница 24: ...89mm Note A combined minimum of 120 squareinchesofopenareaisrequired for the convection air outlet to cool the enclosure Ensure clearances for Convection Air Outlets are met See clearances CV40E single sided in this manual as there are differ ent methods as to how this can be achieved Note This appliance must be in stalled on a solid surface such as a plywood floor which must be the fullwidthandde...

Страница 25: ... Stud 40 1016 mm Chase Vent C40 Chase Vent Framing Clearances Opening for vent 4 4 5 102mmx114mm Min 42 25 1073 mm Framed opening must be between 4 102mm and 4 5 114mm tall andatleast42 25 1073mm wide to accommodate the chase vent The top of the chase vent opening must be 3 or less from the top of the chase enclosure 40 1016 mm Chase Vent ...

Страница 26: ... 11 City Series installation Drywall HeaderStud C40 Chase Vent Finish Detail Finish edges of drywall with trim or corner bead Edge finish must not decrease opening area below 130in 3 25 x 40 or 83 mm x 1016 mm ...

Страница 27: ...g Clearances Page Screw Chase vent to Framing Use at least 3 sets of screws to keep the vent flat against framing Frame wall with finishing material If necessary mark where the chase vent is located before fixing drywall in place Cut hole in finishing material around inside of chase vent Finish edges around opening Drywall ...

Страница 28: ... of the air outlet s Regency Chase Vent Dimensions 3 2 x 40 81mmx1016mm 130in2 Custom chase vent Example dimensions 2 5 x 48 64mmx1219mm 120in2 Reveal at the chase top Example dimensions 2 x 60 51mm x1524mm 120in2 Venting into an adjacent room Minimum 120in2 Note An adjacent room cannot be a garage closed in carport Note The enclosure opening cannot be any lower than 0 3 from the top of the enclos...

Страница 29: ...stall the front grill frame an opening of 4 3 8 H x 39 1 8 W 111 mm H x 994 mm W The finished facing material should be attached and be the same size as the framed opening to eliminate gaps Install the grill and secure in place with one screw on either side installed from the front Note Front grill not used in conjunction with the steel stud framing kit 4 3 8 111 mm 39 1 8 994 mm Maximum 3 76 mm f...

Страница 30: ...y penetrate gas line or damage valve or electrical components Note It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel The appliance is designed to be used with 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual F...

Страница 31: ...ct manual 3 IMPORTANT The interior chase back and sides regardless where appli ance is placed within the home also requires the use of drywall All seams joints MUST be sealed using drywall tape and mud As this appliance has been designed with all hot air escaping through the enclosure using the ventilation grills if hot air is trapped as a result of the hot air escaping through joints or other ope...

Страница 32: ...ue can be used as an alternative Max 3 76 mm To Top of Enclosure 2 120in min Chase vent opening includes 1 2 drywall 117 mm 130 mm 914 mm Max 2 x 4 stud Max 2 x 4 stud CB40 Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 5 8 4 117 mm maximum TV recess using 1 2 13 mm drywall Flush wall TV recess using 1 2 13 mm drywall Max 36 Hearth 1 8 Max 5 Mantle 5 8 Max 4 TV recess with drywall up agai...

Страница 33: ...bove meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public proper...

Страница 34: ... A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4d...

Страница 35: ...14 46DVA SNK14 N A N A N A N A TM 4ST14 N A Snorkel Termination 36 N A N A N A N A N A TM 4ST36 N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Stan...

Страница 36: ...t the 6 pin connector to the back of the Battery Holder 4 Install the Battery Holder in the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Pu...

Страница 37: ...tructions 1 Remove the safety glass and firebox glass see instructions in this manual 2 Remove the screws that hold the vent restrictor plate in place see Diagram 1 3 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 4 Once the vent restrictor plate is in the required position secure with screws Vent Restrictor Position Vent Restrictor Positions Se...

Страница 38: ...ems in combination with the CV40E CB40E DirectVent Gas Fireplace has been tested and listed as a direct vent heater system by Warnock Hersey Intertek The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits include all the parts needed to install the CV...

Страница 39: ...ons of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard s...

Страница 40: ... 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff Optional Rigid Pipe Adapter o 90 Elbow Pipe Length This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct Venting ICC Excel Direct Olympia Chimne...

Страница 41: ...p to 10 feet otherwise rigid venting must be used Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 2 Max B 2 Min 4 Max C 3 Min 5 Max D 4 Min 6 Max E 5 Min 7 Max F 6 Min ...

Страница 42: ... 0 76 over 10 12 to 11 12 3 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 12 7 2 13 over 18 12 to 20 12 7 5 2 29 over 20 12 to 21 12 8 2 44 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct V...

Страница 43: ...n the Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required Maximu...

Страница 44: ...whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Vertical Venting with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required A 1 Min 2 Max...

Страница 45: ...eadapterover the existing inner and outer flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pa...

Страница 46: ...ation cap faces up there are markings on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fire place You may wish to cut the liner shorter to make it more workable Do not bend line...

Страница 47: ...ptor and twist lock for a solid connection Note a Twist lock procedure Four indentations located on the female ends of pipes and fit tings aredesignedto slidestraightontothe male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends Diagram 1 Push the pipe sectionscompletely together thentwist lock one sectio...

Страница 48: ...cked position and sealed 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole shouldbeofsufficientsizetomeettheminimum requirements for clearance to combustibles of 1 1 2 Slip the flashing under the shingles shingles should overlap half the flashing as per Diagram 3 6 Continue to assemble pipe lengths Note If an offset is necessary in the attic toavoido...

Страница 49: ... 6 7 8 VENTING VERTICAL FLEX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length un...

Страница 50: ...iagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To i...

Страница 51: ...installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be sup plie...

Страница 52: ... sharp edges CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation No electrical power supply is required for the gas control to operate 120 Volt AC power is needed for the lights A receptacle box receptacle and cover are provided and located on the left hand side of the unit under the outer base panel Electrical power must ...

Страница 53: ...ndling will not be covered under warranty We recommend handling the glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner prior to operating the appliance Note glass panels mu...

Страница 54: ...DLING We recommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty We recommend handling the glass with supplied vacu...

Страница 55: ... agency is re sponsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions sup plied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit 657 977 includes 1 911 191 Stepper Mot...

Страница 56: ...move pilot retainer clip with pliers and pull off the pilot cap to expose the pilot orifice 14 Unscrew the pilot orifice with the allen key then replace with the LPG pilot orifice and the pilot cap provided in the kit Installer Notice These instructions must be left with the appliance Pilot retainer clip 12 Remove burner orifice with a 3 8 wrench Use another wrench to hold on to the elbow behind t...

Страница 57: ...rials for 1 2 inch to 1 1 8 2 Prior to installing outer liner panels and barrier glass remove finishing trim plates from right and left sides 4 Hand bend attachment tabs so they bend past the magnets to the metal wall inside the opening 3 Insert Clean Trim Faceplate into fireplace opening 5 Affix Clean Trim Faceplate with self tapping screws that are included in the box CLEAN TRIM FACEPLATE INSTAL...

Страница 58: ...back wall of the unit 1 Install inner base panels as shown CV40E OUTER PANELS Outer side panel install Outer front panel install Location of Regency Logo 1 Attach Regency logo to the right hand side of outer front panel The magnets will be positioned under the outer front base panel to secure the logo Install outer front base panel 2 Install side panel the side panel is secured in place by existin...

Страница 59: ... the opposite side and tighten both brackets in place with one screw each 9 With the back panel installed slide in one of the side glass panels 6 Push the panel all the way to the back of the firebox ensuring that the glass is sitting on the bottom corner bracket installed in step 4 Attach top rear bracket as shown Note There is a left and right bracket The left bracket is shown below 13 Install o...

Страница 60: ...ss see manual for instructions 2 Install enamel inner firebox base panel as shown 1 Turn off unit and allow to cool to room temperature Remove the outer safety glass see manual for instructions 2 Attach Regency logo to the right hand side of outer front panel The magnets will be positioned under the outer front base panel to secure the logo Install outer front base panel CV40 inner panel installat...

Страница 61: ...each side Re move drywall finishing edge from right and left side of window open ing using supplied right angle screwdriver 4 Move unit into framed opening at desired height and level unit on all sides Connect gas and electrical see manual EXTENDED VIEW PANEL INSTALLATION Mounting holes Enclosure width CV40E 46 3 4 CV72E 78 Attach base panels Install second stud 8 5 out from first stud 8 5 from st...

Страница 62: ...instructions in unit manual 11 Install glass panels onto base panels glass panels are secured in place with magnets 12 Glass panels should overlap with outer side liner panel as shown below NOTE Remove side liner panel and extended view panel to access firebox Finish to the dashed line only Base panel with finishing Finish wall Install inner panels Install glass panels Correctly installed glass pa...

Страница 63: ...the pilot area Media must be installed on and around burner only in amounts noted below CV40E CB40E Approved Media Where Used Quantity Fireglass starfire copper or black On burner 1 lbs Glowing embers sea wool supplied with unit On burner 1 bag Natural Stones Around burner 1 box 15lbs Ivory Natural Stones Around burner 1 box 15lbs 3 4 Crushed black glass Around burner 3 5lbs Crushed Iceburg chips ...

Страница 64: ...roomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Black Fireglass 1 5lb and glowing wool on the burner as shown below Log Guides location of log guides 2 rear 1 front 5 Clip on the log guides position the rear guides by centering over the second ...

Страница 65: ...nsure the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow is open shown with 3 4 crushed black glass 11 Place Log 4 identify the pin locator and match with the left side pin on Log 1 Rest the other end of Log 4 on the indent in Log 2 as shown below 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the other end...

Страница 66: ...h unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 3 5 2 4 6 7 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Black Fireglass 1 5lb and glowing wool on the burne...

Страница 67: ...st the Log 4 on the indent in Log 2 as shown below 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the Log 5 on the indent in Log 3 as shown below 10 Before placing the next log spread the optional media evenly throughout the burner tray as shown NOTE Ensure the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow...

Страница 68: ... 5 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into pos...

Страница 69: ...nal media evenly throughout the burner tray as shown NOTE Ensure the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow is open shown with 3 4 crushed black glass 8 Place Log 3 to the right front corner of the burner Follow the mea surement as shown 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the Log 5 on th...

Страница 70: ... the wire clamp from the BX cable to the rear of the knock out to secure BX cable Attach the black wire Hot white wire Neutral and ground wire to the appropriate terminals on the receptacle 4 Attach receptacle to electrical box with 2 screws and receptacle cover with 1 screw 5 Run the BX cable from the back of the electrical box and route through the framing using the supplied ties use larger hole...

Страница 71: ... finishing trim kit for this TV box is 1 1 2 deep and designed to be flush to the front of the finished material The framed opening should be 1 1 2 inches deeper compared to all other framing around the appli ance and minus the finished material thickness i e If finished material is 1 2 thick the framed opening should be 1 inch deep 12 Secure TV box to framing with 2 screws per side See below 10 7...

Страница 72: ...rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal oper...

Страница 73: ...ore cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brushasthelogsarefragileandeasilydamaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The ...

Страница 74: ...upper inside front of the firebox and remove 4 Loosen 2 screws on each side of individual inner light cover and remove 5 Remove glass cover by using a flat head screwdriver to pry the tab securing the glass assembly in place 6 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 O...

Страница 75: ...ee instructions in this manual 4 Remove all media and logs if installed set aside 5 Remove inner base panel 7 Remove 16 screws in locations shown below 8 Lift valve tray out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray 9 Reverse steps 6 1 to complete Inner base panel Remove 16 screws securing valve tray CB40E shown 6 Loosen ...

Страница 76: ...d be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of thes...

Страница 77: ...039 Burner Orifice Mount Gasket N S 911 175 Hand Held Remote Control GTMFL SIT 0 584 042 N S 911 187 Remote Receiver Battery Holder 584 103 N S 910 576 Cover Wall Mount White GTM SIT 0 584 803 N S 911 173 Wire Harness IFC No CPI Switch 584 924 N S 911 177 Wire 4 Position IFC Fan Light N S 911 181 Wire Harness Battery Box Proflame II N S 911 192 Power Cord 120 Volts With Connector N S 911 193 Conne...

Страница 78: ...N S 946 781 Crushed Glass Iceberg Chips 3 4in 3 5 Lbs N S 946 735 Firebeads Black 1 Lb Pkg N S 946 736 Firebeads Sangria Luster 1 Lb Pkg N S 946 737 Firebeads Glacier Ice 1 Lb Pkg N S 946 738 Firebeads Caramel Luster 1 Lb Pkg N S 946 739 Firebeads Black 5 Lb Pkg N S 946 740 Firebeads Sangria Luster 5 Lb Pkg N S 946 741 Firebeads Glacier Ice 5 Lb Pkg N S 946 742 Firebeads Caramel Luster 5 Lb Pkg N ...

Страница 79: ...CV40E 11 City Series 79 parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...

Страница 80: ...s Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compo...

Страница 81: ...lation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are ...

Страница 82: ...uld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descrip...

Страница 83: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANA...

Страница 84: ...84 CV40E 11 City Series warranty ...

Страница 85: ...CV40E 11 City Series 85 notes ...

Страница 86: ...86 CV40E 11 City Series notes ...

Страница 87: ...CV40E 11 City Series 87 ...

Страница 88: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _____________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2020 FPI Fireplace Products International L...

Отзывы: