installation
Gas Power Vent Installation-Wiring - End of Line Power Vent
10. Remove front faceplate from power vent unit by removing 4 screws
as shown below.
11. Loosen 4 screws in locations shown below, lift rain guard off screws
(key hole slots).
12. Inside the power vent box--connect the blue and red wires to the
pressure switch as shown below.
13. Bundle the wires together with the supplied grommet and pop the
grommet with wires into the bracket on the roof of the power vent box.
14. Install the second grommet onto the wires and secure grommet
and wires into a bracket located on the side of the power vent box.
15. Connect ground wire to ground lug located at back of power vent box.
16. Connect wires from pressure switch to wires from BX cable--red to
red and blue to blue. Cap paired wires with supplied marrette.
Red Wire
Ground
Blue Wire
Grommet in bracket
Grommet in bracket
Red to Red
Black to Black
Black to White
17. Connect remaining wires from the power vent motor to the BX
cable- black to black and black to white. Cap paired wires with sup-
plied marrette.
NOTE: After exposure to heat--white wire will appear yellow -- blue
wires will appear green.
18. Reinstall rain guard and tighten screws.
19. Reinstall front faceplate with 4 screws.
Note: This power vent cap can be serviced externally or internally. If access
to the exterior is not possible once installed due to height/location of
the termination location, it is highly recommended that an access panel
be placed near the rear of the termination inside of the enclosure where
the power vent cap is located. The access panel should be large/close
enough to be able to service the power vent cap. See maintenance section
of manual to see how servicing is completed internally.
NOTE:
Cut off existing
connectors from
fan motor and strip
back to expose wires
before connecting.