City Series CB40EPV
|
25
requirements
installer's information
Chase Enclosure
Max
3
”
(76 mm)
Ceiling
Ceiling
Top of chase enclosure
Max
3
”
(76 mm)
Stud
Stud
Stud
Stud
40”
(1016 mm)
Chase Vent
C40 Chase Vent Framing Clearances
Opening for vent
4”-4.5”
(102 mm x 114 mm)
Min 42.25”
(1073 mm)
Framed
o
pening must be between 4”
(102 mm)
and 4.5”
(114 mm)
tall, and at least 42.25”
(1073 mm)
wide
to acco
m
modate the
c
hase vent.
The top of the chase vent opening must be
3
” or less from the top of the
chase enclosure.
40”
(1016 mm)
Chase Vent
Top of chase enclosure
In the example above, the ceiling does not
meet the requirement as it is higher than
the specified minimum.
Top of chase
enclosure is sealed off to
meet the 0-3 (76 mm) requirement.
Top of chase enclosure
Minimum 120sq. inch opening
Minimum 120sq. inch opening
When choosing to install the ventilation openings from the front or both sides, The top of the ventilation opening cannot be any lower than 0-3" from the top
of the chase enclosure for all installations.
Minimum height of enclosure from base of appliance is 63".
A minimum 120in
2
opening in the enclosure is required to maintain safe operating temperatures. This can be achieved in a number of ways including the
examples shown in this manual.
IMPORTANT: The interior chase enclosure (top, back and sides), regardless of where appliance is placed within the home, requires the use of either dry-
wall or other means such as insulation, plywood, wood studs, etc. to prevent heat from escaping anywhere above the enclosure.
One of the following methods must be used to prevent the heat from escaping into the cavity of the enclosure.
a. If choosing drywall, joints MUST be sealed using drywall tape and mud.
b. Insulation, plywood, wood studs, etc. installed tightly with no gaps, seams.
As this appliance has been designed with all hot air escaping through the chase enclosure ventilation openings only, if hot air is trapped as a result of the
hot air escaping through joints, crevasses, open studs,or other openings within the enclosure above, this will change the clearances within the enclosure
causing the enclosure to over heat. It is vital that all the hot air from within the enclosure exits through the ventilation openings only.
Ensure that the ventilation openings are made as such to prevent debris, objects from falling into the enclosure.
Warning: DO NOT cover or place objects in front of the ventialtion opening air outlet(s).