![Regency Fireplace Products CB40EPV-LP Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/regency-fireplace-products/cb40epv-lp/cb40epv-lp_owners-and-installation-manual_1433869027.webp)
City Series CB40EPV
|
27
installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Clearances CB40EPV
Clearance: 3 sided
Dimension
Measured From:
A: From Floor
Min. 0"
Bottom of Fireplace Opening
A1 : Mantel Height (min.)
**
Top of Fireplace Opening
B: Sidewall (on one side)
8-1/2" (216 mm)
Side of Fireplace Opening
C: Enclosure Width (min.)
48-7/16" (1230 mm)
Minimum inside dimensions
D: Mantel Depth (max.)
**
E: Alcove Width
84" (2134 mm)
Side wall to side wall (min.)
F: Alcove Depth
36" (914 mm)
Front of Unit
G: To Enclosure Ceiling (min/max)
0-3" (0-76 mm)
From top of enclosure
H: Convection Air outlet
120 sq. inches (min)
* Top/front or side of enclosure
I: Enclosure Depth (min.)
19" (483 mm)
Minimum inside dimensions
J: Opening Height
15-1/16" (383 mm)
Bottom/Top of Fireplace Opening
K: To Ceiling (min) All 3 sides
1-1/2" (38 mm)
To Top of Ceiling
L: Chase Enclosure (min.)
63" (1600 mm)
From base of unit/floor
M: Clearance to Sprinkler Head (Min.)
36" (914 mm)
Perpendicular from chase grill
Hearth
0"
No hearth required
**
See mantel clearances chart in this manual
Flue Clearances to Combustibles
Horizontal - Top
3" (76 mm)
Horizontal - Side
2" (51 mm)
Horizontal - Bottom
2" (51 mm)
Vertical
2" (51 mm)
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2" (38 mm)
* A minimum of 120 square inches of open area, not lower than 3" from top of enclosure, required for all
installations — this can be achieved by having an open area in front, each side, and/or above as shown
in the four diagrams on the next page.
The
HeatWave
Duct Kit has differ-
ent clearance and framing require-
ments, check the
HeatWave
manual
for details.
E
F
Alcove
L
Chase grill
Sprinkler
Side view
M
Содержание CB40EPV-LP
Страница 113: ...City Series CB40EPV 113 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Страница 120: ...120 City Series CB40EPV ...
Страница 121: ...City Series CB40EPV 121 notes ...
Страница 122: ...122 City Series CB40EPV notes ...
Страница 123: ...City Series CB40EPV 123 warranty ...