maintenance
Power Vent Maintenance - External Power Vent Access
Inline Power Vent
1. Remove 4 screws from the cover plate.
2. Remove the pressure switch by disconnecting its red and blue wires (Dia-
gram 2). The longest silicone tube is connected to the pressure switch side
labelled "P" and the shorter silicone tube is connected to the side labelled "V".
3. Loosen the 2 screws securing the pressure switch bracket to the power vent
bracket mount (Diagram 3). Once the pressure switch is free, it is possible
to replace it by removing (1) one Phillips head screw holding the pressure
switch to the mounting bracket (Diagram 4).
Replacing the power vent motor:
1. Turn off power supply.
2. Loosen 6 x 1/4” (6 mm) hex screws slightly.
3. Turn power vent motor counter-clockwise and lift out. (Diagram 5)
4. Disconnect power to motor by disconnecting black and black wire and white
and black wire (Diagram 6) power vent motor is now free from the unit.