City Series CB40EPV
installer's information
Levelling bolts
Levelling Bolts
There are four levelling bolts - two on each side
that can be adjusted if required.
These can be adjusted using the open end wrench
provided with the manual package.
Locating Your
Gas Fireplace
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CB40EPV Direct Vent Gas Fireplace can
be installed framed out into the room as in D
and E. See Diagram 1.
E
Diagram 1
CB40EPV
D)
3 sided-CB40EPV (corner install)
E)
3 sided-CB40EPV
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CB40EPV Direct Vent Gas Fireplace is
approved for alcove installations, see "Clear-
ances" section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior
Vent Termination Locations" section.
Unit Assembly Prior to Installation
tooltip
Back Standoff Assembly CB40EPV
Take each standoff off the unit by removing one
screw. Bend into the correct shape (see above). Slot
the 2 tabs of the stand off into the slots in the unit
and attach the other end with one screw.
Access Panel Removal
The front access panel may be removed for ease
of hooking up gas and electrical. Once complete
ensure that the access panel is reinstalled prior to
any finishing.
The CB40EPV has 8 screws to remove access cover.
See locations in diagrams to the right.
8 screws
Nailing
strips
Nailing Strips CB40EPV
Nailing strips are shipped with the appliance and will
need to be attached. Note that the nailing strips are
not required if using the optional chase or extended
framing kit and may be recycled.
1. Secure nailing strip to appliance with 2 screws
per side.
2. Secure nailing strips to framing using wood or
metal screws.
Before you Start
The CB40EPV has only 2 standoffs at the back that need assembly before installation.