installation
Gas Power Vent Installation - Framing - Inline Power Vent Terminations (Part # 666-945)
920-210a
06.08.20
8
CV72EPV / CB72EPVCB40EPV/CC40EPV/CV40EPV
Inline Power Vent Vertical or Hortizontal Installation Instructions
• The inline power vent can be mounted directly onto a wall, ceiling, stud or truss. Additional supports can be built to support the power vent if
needed.
• The inline power vent can be oriented in any way if the access panel is accessible.
NOTE: The inline power vent will have a directional arrow which must be pointed away from the appliance.
Diagram 1: Inline power
vent oriented vertically
Diagram 2: Inline power
vent oriented horizontally
Pressure switch orientation if inline power
vent is oriented vertically (see Diagram 1)
Pressure switch orientation if inline power
vent is oriented horizontally (see Diagram 2)
IMPORTANT:
The pressure switch must be oriented as shown
below:
Gas Power Vent Installation-Framing
Inline Power Vent Terminations
Termination
End
Directional
Arrows
Termination
End
Appliance
End
Appliance
End
NOTE: If the power vent is terminated vertically, no action
is required for the pressure switch. If in a horizontal
position, the pressure switch will need to be rotated. See
instructions on next page.
Vent at appliance end
Vent at appliance
end
Содержание CB40EPV-LP
Страница 113: ...City Series CB40EPV 113 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Страница 120: ...120 City Series CB40EPV ...
Страница 121: ...City Series CB40EPV 121 notes ...
Страница 122: ...122 City Series CB40EPV notes ...
Страница 123: ...City Series CB40EPV 123 warranty ...