Termination
The RDL-3000 PPS port has programmable termination and does not require an
external terminator to be installed at the end of the daisy-chain See the following
configuration information .
Figure 54 - Sync - Synchronization Cabling Example - Without GPS
Synchronization Cable Kit
One GPS Synchronization (Cable) Kit is required for each 'sync listener' sector
controller. For example, installing four collocated bases stations requires one kit for each
'sync listener' (total of three GPS synchronization cable kits). The GPS Synchronization
Kit is designed to accommodate most installations. This kit includes the following items:
TNC Tee Adapter
6 m (19.5 ft) LMR-195 50 ohm synchronization cable with TNC / M connectors.
Figure 55 - Sync - Synchronization Cable Kit