Telnet Access
Use the following steps to establish a Telnet session with the RDL-3000.
1.
On the PC, open a Telnet client and enter the unit IP address. The RDL-3000 factory
default IP is '192.168.25.2'.
2.
Login to the RDL-3000 using the assigned username and password. The default
username is 'admin', and the default password is 'admin'.
For example,
telnet 192.168.25.2
username: admin
password: *****
Web Browser
Use the following steps to establish a Web session with the RDL-3000.
1.
On the PC, open a browser and enter the unit RDL-3000 IP address in the browser
address bar. The factory default IP address is 192.168.25.2.
2.
Login to the RDL-3000 using the assigned username and password. The default
username is 'admin', and the default password is 'admin'.
Figure 41: Procedures -
Configuration -
Login Screen
5.5.2
Step 2: Restore Default Settings
When first deploying an RDL-3000, it is recommended to perform a factory reset to
initialize the system parameters.
Factory Reset
Web:
1. Login to the RDL-3000 Web interface
2. Click
Configuration->Factory Defaults
Telnet:
1. Login to the RDL-3000 Telnet interface
2. Enter the command:
save defaultconfig