RDL-3000
INSTALLATION GUIDELINES
70-00159-01-06
Proprietary Redline Communications © 2012
Page
47
of 65
kune 12, 2012
5.5
Configuration
Use the following steps to setup a basic link between the PMP sector controller and a
single subscriber:
1.
Setup the test PC and login to the Web or CLI management interface.
2.
Factory reset the RDL-3000
3.
Enter the options keys
4.
Configure the basic wireless parameters
5.
Provision a Link, Service, and Service Group
5.5.1
Step 1: Login to RDL-3000
The RDL-3000 can be configured and monitored using Telnet or a standard Web
browser (e.g., Internet Explorer 6.0 or higher). The following procedures require a PC
equipped with a Web browser, Ethernet port, and an Ethernet Cat-5e crossover cable for
connecting the PC to the PoE power adapter.
Figure 40: Procedures - Basic Wiring
Configuration for Web/Telnet Access
The IP address of the test PC must be on the same subnet as the RDL-3000. For
example:
IP address = 192.168.25.11
Net Mask =
255.255.255.0