RDL-3000
FAMILY
USER MANUAL
70-00158-03-00
Proprietary Redline Communications © 2015
Page
166
of 254
April 17, 2015
7.1.2
Modify CIR / PIR Settings in a Maintenance Window
Use this procedure to modify CIR/PIR settings for services on STID link templates during
a scheduled maintenance window when it is acceptable for the sector controller to be
taken offline for a short period. The operator must reboot the sector controller at the end
of the procedure.
1.
Verify the maintenance window period is active.
2.
Login to the sector controller Web interface.
3.
Select
Provisioning -> Subscriber Links
to view all configured links.
4.
Identify the (STID) link with services requiring changes to the CIR / PIR settings.
a) Click to show all services associated with that link.
b) Click on the name of a service to edit the service configuration and enter new CIR
/ PIR settings.
c) Save the modified service configuration.
5.
Repeat step 4 as required to modify services for other STID templates.
6.
Reboot the sector controller to activate all changes.
IMPORTANT
: Failure to reboot the sector controller at the end of this procedure will
result in LOSS OF COMMUNICATIONS to all subscribers on the sector controller.
This completes the procedure.
7.2
ID Mapping
The following table lists the ID ranges assigned for each provisioning type.
Table 31
:
Ref. - RDL-3000 ID Ranges
Description
ID Range
Total
Links
4-127
124
Service Groups
128-159
32
Services
160-511
352
7.3
Radio Types
Type of radio installed. Refer to the Web General Information screen or CLI 'get
radiotype' command.
Table 32
:
Ref. -RDL-3000 Radio Types
Radio Type
Frequency Range (MHz)
T072x
470 - 698
T212x
2000 - 2300
T202x
2300 - 2800
T352x
3300 - 3800
T502x
4940 - 5875