8. Pb (Lead-acid) battery program
14
Set the sequence on the left and the number of cycle
on the right. You can use this function for balancing,
refreshing and break-in the battery. To avoid rising
temperature of the battery, there will a brief cool-off
period that already fixed at ‘User setting’ after each
charge and discharge process. The cycling number
ranges from 1 to 5.
To stop the process, press Batt type/Stop key once.
You can change the discharge or charge current by
pressing Start/Enter key once during the process. The
audible sound indicates the end of the process.
At the end of the process, you can see charged or
discharged electric capacities of the battery at each
cyclic process
By pressing INC or DEC button, the screeen shows the
result of each cycle in order.
This is programmed for charging Pb (lead-acid) battery with nominal voltage from 2 to 20v.
Pb batteries can only deliver low current compared to their capacity. The optimal charge
current is 1/10th of the capacity. Pb batteries must not be charged rapidly. Always follow
the instructions supplied by the battery manufacturer.
When you are ready to alter the parameter value, press Start/Enter to make it blink, then
change the value with INC or DEC key. The value will be stored by pressing
Start/Enter key once
Start the charge process by pressing Start/Enter key
for more than 3 seconds.
The screen displays the state of the charging process.
To stop charging, press Batt type/Stop key once.
An audible sound indicates the end of the charging
process.
Set up the charge current on the left and the nominal
voltage of the battery on the right. The charge current
ranges from 0.1 to 7.0A, and the voltage should be
matched with the battery being charged