12
-
6.5 Discharging Lithium battery
The value of discharge current on the left side of
screen may not exceed 1C for maximum safety
and the
final voltage on the right should not be under
the voltage level that is recommended by the battery
manufacturer to avoid deep discharge.
To start discharge, press
Start/ Enter
key for more
than 3 seconds.
This shows the present state of discharge. To stop
discharging press
Batt type/Stop
key once.
6.6 Voltage balancing and monitoring while discharging
The charger monitors the voltage of individual cells during 'storage-mode' and
'discharge' of a Lithium battery pack. It tries to e q u a l t h e v o l t a g e o f e a c h c e l l .
For this feature, the individual plug of the battery pack should be connected to the
individual port of the charger.
If the voltage of any one or more cells varies abnormally during the procedure, It
terminates the process with an error message. If this happens, the battery
pack contains a bad cell, or a bad connection. To check which cell is bad press
the INC button at the time of error.
The charger has detected that the voltage of one cell
in the Lithium battery pack is too low.
In this case, the 4th cell is bad. If there is a
connection-break of the cable or plug, the voltage value
may show zero.