Charge the GoBlock | 15
Charge Directly From a Vehicle Alternator
Connect directly to your vehicles alternator via an extension cable (not included) to the Auxiliary
Anderson™ Input on the back of the GoBlock. Use a suitable adaptor if the power output connector
on you vehicle is not an Anderson™ connector.
Visit the REDARC website for detailed instructions on how to run a direct wire from your start
battery to charge via the Auxiliary Anderson Input.
The extension cable positive wire must be fused to 60 A. Refer to the
an appropriate cable gauge for your installation.
NOTICE
REDARC recommends only using genuine Anderson™ connectors manufactured by
Anderson Power Products
®
for GoBlock installations. Counterfeit or generic connectors may
result in a poor quality connection.
Charging from a vehicle alternator via an Anderson™ cable.
CABLE SIZING
Purchase cable length and gauge to suit your individual installation. Cable length refers to the total
cable length of the install (po negative cable length). Always choose a wire cross sectional
area equal to or greater than what is specified below. The selected cable must be capable of
carrying a minimum of 60 A.
Cable Install Length
Recommended Wire
Cross Section
Closest Equivalent
(BAE, B&S, AWG)
1 – 5 m
3' – 16'
≥ 13.56 mm²