Troubleshooting | 33
ALERT CODE IDENTIFICATION AND RESOLUTION
In the event of an Alert, the Control Button LED will flash red and an Alert Code will be
displayed by the Battery Level LEDs.
Recovery — Internal Fault
Charge-back fault — something went wrong during Recovery.
Fault resolution:
1.
If you are attempting to use the Recovery function via the auxiliary input while the
GoBlock is docked in the PowerDock, remove the GoBlock from the dock and try to
initiate Recovery again.
Recovery — No Battery Connected
Output battery can not be detected.
1.
Check that a vehicle start battery is connected to the GoBlock or PowerDock.
2.
Check for loose connections to the vehicle start battery.
Over Temperature
GoBlock is too hot — unit temperature is above 45°C / 113°F (when charging), or
60°C / 140°F (when discharging).
1.
Immediately move the GoBlock to a cooler/shaded location. When the unit has
returned to operating temperature, the fault will resolve.
Over Temperature Alarm
Note that if the GoBlock exceeds 60°C / 140°F an alarm tone will sound every
10 seconds. Immediately move the GoBlock to a cooler/shaded location. The alarm can
then be silenced for 10 minutes by pressing the Control Button. If, after 10 minutes, the
GoBlock temperature still exceeds 60°C / 140°F then the alarm tone will recommence.
If the GoBlock exceeds 70°C / 140°F, an alarm tone will sound every 10 seconds, and
cannot be silenced until the unit temperature is below 70°C / 140°F.
NOTICE:
Failure to resolve an Over Temperature alarm may result in damage to the
GoBlock's internal battery.
Under Temperature
GoBlock is too cold — temperature is below 0°C / 32°F (when charging), or −20°C /
−40°F (when discharging).
1.
Move the GoBlock to a warmer location. When the unit has returned to operating
temperature, the fault will resolve.